Hollis 200LX DC7 Yoke Dive Regulator Set
In stock — ships from Irvine, CA
This item is currently on backorder. Order now to reserve yours, and we will ship it as soon as it is back in stock.
Hollis 200LX DC7 Yoke Dive Regulator Set - YOKE is backordered and will ship as soon as it is back in stock.
Pickup available at In Store
Usually ready in 2 hours
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Save with Open Box or Used Purchase
Save with a package
Ready-made packages that include this item
Product Information
The Hollis 200LX + DCX Yoke Dive Regulator Set pairs the pneumatically balanced 200LX second stage with the DCX first stage in a Yoke (INT) connection, giving divers a flagship regulator built for consistent breathing performance in saltwater, reef, and demanding dive conditions. The set includes a MiFlex braided hose and is backed by Hollis's lifetime warranty with free parts for life.
Who it is for
This set suits recreational and technical divers who want a dependable regulator for reef diving, boat diving, and cooler or more demanding conditions. The DCX first stage's over-balanced diaphragm design and environmental sealing make it a good match for divers who travel between warm and cold water, while the diver-adjustable inhalation knob and reversible demand valve let both left and right-handed divers fine-tune the second stage to their preference.
Key details
- Second stage: Hollis 200LX, pneumatically balanced, PVD-plated brass valve for smooth, easy breathing
- First stage: Hollis DCX, over-balanced diaphragm design with environmental sealing against corrosion, contaminants, and icing
- DCX ports: 2 high-pressure (HP) and 5 low-pressure (LP) ports, including a 5th LP port for sidemount or twin-cylinder hose routing
- Connection: Yoke (INT), with a swivel turret on the first stage for low-pressure hose routing
- Demand valve reverses between right-handed and left-handed hose configuration without specialty tools
- Adjustable Dive/Pre-Dive switch with a large Venturi lever and soft rubber grip
- Orthodontic mouthpiece with dual color tabs and PVD-plated stainless steel metal ring, knob, and end cap
- MiFlex braided hose included
- Service interval: 2 years with inspection; covered by Hollis's lifetime warranty and free parts for life
Compatibility and sizing
This listing is the Yoke (INT) version of the 200LX + DCX set; a DIN version is also offered by Hollis. The DCX first stage's 5th LP port supports hose routing for sidemount or twin-cylinder configurations in addition to standard backmount setups.
What's in the box
- 200LX second stage
- DCX first stage
- MiFlex braided hose
DiveCatalog.com is an authorized Hollis dealer and a dive shop in Irvine, California, serving divers since 2003. Call or chat with us at 888-701-4017 if you have questions about Yoke versus DIN fit or hose routing for your configuration.
- Pneumatically balanced valve. PVD-plated brass valve in the 200LX second stage delivers smooth, easy breathing.
- Reversible demand valve. Converts between right-handed and left-handed hose configuration without specialty tools or recalibration.
- Diver-adjustable inhalation knob. Lets the diver customize inhalation effort at depth.
- Adjustable Dive/Pre-Dive switch. Large Venturi lever with a soft rubber grip for easy locating and use.
- Ergonomic exhaust channels. Direct bubbles away from the diver's field of view and reduce exhaust effort.
- Improved orthodontic mouthpiece. Features dual color tabs.
- PVD-plated finish. Stainless steel metal ring, adjustable knob, and Dive/Pre-Dive end cap.
- MiFlex braided hose included. Braided hose connects the DCX first stage to the 200LX second stage.
- DCX over-balanced first stage. Provides progressively greater intermediate pressure as depth and gas density increase.
- Environmental sealing. Protects the DCX first stage from internal corrosion, contaminants, and icing.
- 5 low-pressure ports. The DCX's 5th LP port allows hose routing for sidemount or twin-cylinder setups.
- Lifetime warranty with free parts for life. Backed by a 2-year service interval with inspection.
| Brand | Hollis |
| Model | 200LX second stage with DCX first stage |
| Connection | Yoke (INT) |
| Second Stage | 200LX, pneumatically balanced, PVD-plated brass valve |
| First Stage | DCX, over-balanced diaphragm design, environmentally sealed |
| First Stage Ports | 2 high-pressure (HP) ports, 5 low-pressure (LP) ports |
| Demand Valve | Reversible for left or right hose routing |
| Inhalation Adjustment | Diver-adjustable knob |
| Venturi | Adjustable Dive/Pre-Dive lever with rubber grip |
| Mouthpiece | Orthodontic with dual color tabs |
| Finish | PVD-plated stainless steel ring, knob, and end cap |
| Hose | MiFlex braided |
| Service Interval | 2 years with inspection |
| Warranty | Lifetime warranty, free parts for life |
| SKU | 240.2010.07.M |
| UPC | 020545209928 |
- 200LX second stage
- DCX first stage
- MiFlex braided hose
⚠️ WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, visit www.P65Warnings.ca.gov.
Frequently Asked Questions
How often does a scuba regulator need servicing?
Follow the interval in your regulator's manual, since manufacturers commonly specify an annual inspection or a set number of dives and many warranties depend on it. A regulator is life-support equipment, so service belongs with a factory-trained technician rather than being attempted at home. Have it looked at sooner than scheduled if you notice increased breathing effort, free-flow, bubbles, or water in the second stage.
How do I rinse and care for a regulator after diving?
Make sure the dust cap is dry and firmly seated over the first-stage inlet before the regulator goes anywhere near water, because water inside the first stage is the leading cause of internal corrosion. Rinse in fresh water without pressing the purge button, since purging while depressurized can draw water back into the second stage. Shake out the water and hang it to dry with the hoses in wide, gentle loops rather than tight bends.
Can I fly with a scuba regulator?
Regulators travel well and are usually best carried in hand luggage where they will not be crushed or lost. A regulator holds no gas of its own, so there is nothing inherently problematic about it on an aircraft, though the airline and security screeners always have the final say. Pack it dry with the dust cap in place, in a padded regulator bag or wrapped in soft gear.
Can I use my regulator with nitrox?
Many modern regulators are supplied as suitable for nitrox mixes up to 40 percent oxygen, which is the widely used recreational industry standard, while anything above that requires dedicated oxygen-clean equipment and procedures. Confirm what your specific regulator's manual states, and follow your nitrox training and your fill station's requirements. Never assume a regulator is oxygen-service clean simply because it looks clean or is new.
What is the difference between DIN and yoke regulators?
A yoke (A-clamp) fitting clamps over the tank valve and is the most common connection across much of the recreational world, while a DIN fitting screws into the valve and is standard in much of Europe and in technical diving. DIN captures the o-ring inside the threads, which many divers consider more secure, but yoke is often what rental cylinders provide. Adapters exist in both directions, so check what is used where you dive before deciding.
What is the octopus regulator for?
The octopus is your backup second stage, carried so you can share air with a buddy who is out of gas, or breathe from it yourself if your primary fails or free-flows. It is normally on a longer, brightly colored hose so it is easy to find and hand over under stress. Secure it in the triangle between your chin and the bottom of your rib cage so it is instantly accessible and not dragging through sand or coral.
How should I store a regulator between dive trips?
Store it fully dry, out of sunlight, with the dust cap in place and the hoses in wide loops rather than tightly coiled. Avoid hanging it by the second stages for long periods, which stresses the hose fittings; laying it flat in a padded bag or hanging it by the first stage is kinder. If it has sat unused for a long stretch, have it checked before your next trip rather than assuming it is ready to dive.
Is this the Hollis 200LX with DC7 or DCX first stage?
This set pairs the Hollis 200LX second stage with the DCX first stage, matching Hollis's current manufacturer listing for this SKU and UPC. The DCX first stage uses an over-balanced diaphragm design with environmental sealing and offers 2 high-pressure and 5 low-pressure ports, including a 5th LP port for sidemount or twin-cylinder hose routing.
Does the DCX first stage work for sidemount or twin-cylinder diving?
Yes. The DCX first stage includes a 5th low-pressure port specifically for routing hoses in sidemount or twin-cylinder configurations, in addition to standard backmount setups. Its swivel turret also helps with low-pressure hose routing flexibility.
Is this regulator set available in DIN as well as Yoke?
Yes, Hollis offers the 200LX + DCX set in both DIN and Yoke (INT) connection options. This specific listing is the Yoke version; contact DiveCatalog.com if you need the DIN configuration.
What warranty comes with the Hollis 200LX + DCX regulator set?
Hollis backs this set with a lifetime warranty and free parts for life, along with a 2-year service interval that includes inspection.













