Mares 26XR with HR Single Tank Regulator Set
In stock — ships from Irvine, CA
This item is currently on backorder. Order now to reserve yours, and we will ship it as soon as it is back in stock.
Mares 26XR with HR Single Tank Regulator Set is backordered and will ship as soon as it is back in stock.
Pickup available at In Store
Usually ready in 2 hours
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Product Information
The Mares 26XR with HR Single Tank Regulator Set pairs the 26XR first stage with two HR second stages on a single cylinder, built around a long hose configuration with a 60 cm and a 210 cm rubber LP hose and a G5/8 connection rated to 300 BAR (DIN).
Who it is for
This set is designed for divers who prefer a long hose setup on a single cylinder and who want a straightforward path to twinset diving later on, since a second first stage can be added to the same configuration down the road. The 26XR first stage suits single cylinder or stage cylinder use, making this set an entry point for divers moving toward twin cylinders.
Key details
- 26XR first stage with a balanced diaphragm design and Auto Sealing Technology (AST) to help keep the mechanism dry, plus a TBP Dry Kit for environmental sealing.
- 4 radial and 1 vertical low pressure port (5 LP ports total), 2 symmetrical, pre-oriented HP ports, and snag-free hose positioning.
- First stage weight: 683 g / 24 oz in DIN, 680 g / 23.9 oz in NX.
- HR second stages use an ultralight technopolymer case, the Adjustable Breathing Comfort system, the V.A.D. System with a curved bypass, Pneumatically Assisted Design (PAD), and an oversized purge button. Second stage weight: 220 g / 7.7 oz.
- G5/8 connection rated to 300 BAR (DIN); Mares lists this set in Black with a Nitrox rating of NR.
What's in the box
- One 26XR first stage
- Two HR second stages
- Rubber LP hose, 60 cm / 24 in
- Rubber LP hose, 210 cm / 7 ft
DiveCatalog.com is an authorized Mares dealer and a dive shop in Irvine, California since 2003. Call or chat with us if you have questions about fit, hose routing, or compatibility with a future twinset upgrade.
- Adjustable Breathing Comfort system: lets the diver control inhalation effort on the HR second stages.
- V.A.D. System with curved bypass: delivers natural, high air flow at any depth.
- Ultralight technopolymer case: simple, high-performance construction for the second stages.
- PAD (Pneumatically Assisted Design): adds comfort during inhalation.
- Oversized purge button: easy to use, even with thick gloves.
- Rubber LP hoses: 60 cm and 210 cm lengths, with greater resistance to cuts, abrasions, bursting, UV, and less floating.
- 26XR first stage: balanced diaphragm design with Auto Sealing Technology (AST) to help keep the first stage dry, suitable for single cylinder or stage cylinder configurations.
- Natural DFC on all LP ports: supports high air flow at any depth.
- TBP Dry Kit: environmentally sealed for performance on cold water dives.
- Port layout: 4 radial LP ports, 1 vertical LP port, and 2 symmetrical, pre-oriented HP ports for flexible hose positioning.
- G5/8 connection: rated to 300 BAR (DIN).
| Brand | Mares |
| Model | 26XR with HR second stage, single tank set |
| Color | Black |
| Nitrox Rating | NR |
| First Stage | 26XR, sealed, extreme cold water |
| Second Stage Material | Ultralight technopolymer |
| HP Ports | 2 (7/16 in UNF) |
| LP Ports | 4 radial plus 1 vertical (3/8 in UNF), 5 total |
| First Stage Weight | 683 g / 24 oz DIN; 680 g / 23.9 oz NX |
| Second Stage Weight | 220 g / 7.7 oz |
| Hoses | Rubber, 60 cm / 24 in and 210 cm / 7 ft |
| Connection | G5/8, 300 BAR (DIN) |
- One 26XR first stage
- Two HR second stages
- Rubber LP hose, 60 cm / 24 in
- Rubber LP hose, 210 cm / 7 ft
⚠️ WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, visit www.P65Warnings.ca.gov.
Frequently Asked Questions
How often does a scuba regulator need servicing?
Follow the interval in your regulator's manual, since manufacturers commonly specify an annual inspection or a set number of dives and many warranties depend on it. A regulator is life-support equipment, so service belongs with a factory-trained technician rather than being attempted at home. Have it looked at sooner than scheduled if you notice increased breathing effort, free-flow, bubbles, or water in the second stage.
How do I rinse and care for a regulator after diving?
Make sure the dust cap is dry and firmly seated over the first-stage inlet before the regulator goes anywhere near water, because water inside the first stage is the leading cause of internal corrosion. Rinse in fresh water without pressing the purge button, since purging while depressurized can draw water back into the second stage. Shake out the water and hang it to dry with the hoses in wide, gentle loops rather than tight bends.
Can I fly with a scuba regulator?
Regulators travel well and are usually best carried in hand luggage where they will not be crushed or lost. A regulator holds no gas of its own, so there is nothing inherently problematic about it on an aircraft, though the airline and security screeners always have the final say. Pack it dry with the dust cap in place, in a padded regulator bag or wrapped in soft gear.
Can I use my regulator with nitrox?
Many modern regulators are supplied as suitable for nitrox mixes up to 40 percent oxygen, which is the widely used recreational industry standard, while anything above that requires dedicated oxygen-clean equipment and procedures. Confirm what your specific regulator's manual states, and follow your nitrox training and your fill station's requirements. Never assume a regulator is oxygen-service clean simply because it looks clean or is new.
What is the difference between DIN and yoke regulators?
A yoke (A-clamp) fitting clamps over the tank valve and is the most common connection across much of the recreational world, while a DIN fitting screws into the valve and is standard in much of Europe and in technical diving. DIN captures the o-ring inside the threads, which many divers consider more secure, but yoke is often what rental cylinders provide. Adapters exist in both directions, so check what is used where you dive before deciding.
What is the octopus regulator for?
The octopus is your backup second stage, carried so you can share air with a buddy who is out of gas, or breathe from it yourself if your primary fails or free-flows. It is normally on a longer, brightly colored hose so it is easy to find and hand over under stress. Secure it in the triangle between your chin and the bottom of your rib cage so it is instantly accessible and not dragging through sand or coral.
How should I store a regulator between dive trips?
Store it fully dry, out of sunlight, with the dust cap in place and the hoses in wide loops rather than tightly coiled. Avoid hanging it by the second stages for long periods, which stresses the hose fittings; laying it flat in a padded bag or hanging it by the first stage is kinder. If it has sat unused for a long stretch, have it checked before your next trip rather than assuming it is ready to dive.
Can the Mares 26XR-HR Single Tank Set be upgraded for twinset diving?
Yes. Mares designs this set as an entry point for recreational divers who want to move into twin-cylinder diving later, since a second first stage can be added to the existing 26XR configuration to create a twinset setup when you are ready.
What hoses come with the Mares 26XR-HR Single Tank Set?
The set includes two soft rubber low pressure hoses, one measuring 60 cm (24 in) and one measuring 210 cm (7 ft), sized for a long hose configuration on a single cylinder and ready for immediate use.
What DIN rating does the 26XR first stage have?
The 26XR first stage uses a G5/8 connection rated to 300 BAR (DIN).
How many low pressure ports does the 26XR first stage have?
The 26XR first stage has 4 radial low pressure ports plus 1 vertical low pressure port, for 5 LP ports total, along with 2 symmetrical, pre-oriented high pressure ports for flexible hose routing.















