Mares Regulator Dual 2S Black
In stock — ships from Irvine, CA
This item is currently on backorder. Order now to reserve yours, and we will ship it as soon as it is back in stock.
Mares Regulator Dual 2S Black - Black / Din is backordered and will ship as soon as it is back in stock.
Pickup available at In Store
Usually ready in 2 hours
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Save with a package
Ready-made packages that include this item
Save $228.82 (21% off)
Save $228.82 (21% off)
Product Information
The Mares Dual 2S is a first and second stage scuba regulator set built around a piston-controlled 2S first stage and a technopolymer dual second stage, available in Black with a choice of DIN or Yoke (INT) connection.
Who it is for
This regulator set suits divers who want a compact, rugged first stage paired with a lightweight second stage for everyday recreational diving. The sandblasted first stage finish is built to withstand rugged conditions, and the second stage's ultralight technopolymer construction is intended for durability along with a balanced breathing feel.
Key details
- 2S first stage uses piston control with a scratch-resistant sandblasted finish and a dedicated RFID chip holder for service history tracking.
- Dual second stage is made of ultralight technopolymer and uses Vortex Assisted Design (VAD) with a curved bypass tube that creates a vortex and low-pressure center to aid diaphragm movement for natural breathing at diving depths.
- A large purge button is sized for easy operation even with thick gloves.
- First stage weight is 608 g (21.4 oz) in the INT version and 440 g (15.5 oz) in the DIN version; second stage weight is 182 g (6.4 oz); total weight is 921 g (32.5 oz) INT or 753 g (26.6 oz) DIN.
- First stage ports are 1 HP (7/16 in UNF) and 4 LP (3/8 in UNF); the hose is a 75 cm Superflex hose.
Compatibility and sizing
The Dual 2S is offered in Black with a connection selector for DIN or INT (Yoke), corresponding to SKUs 416275DINBK (DIN) and 416275INTBK (Yoke), so divers can choose the fitting that matches their tank valve.
DiveCatalog.com is an authorized Mares dealer and a dive shop in Irvine, California, open since 2003. Call 888-701-4017 or start a chat if you have questions about DIN versus Yoke fit or compatibility with your current setup.
- 2S First Stage: Compact piston-controlled first stage with a scratch-resistant sandblasted finish for lasting durability.
- RFID Chip Holder: Dedicated first-stage RFID chip holder supports service history tracking.
- Dual Second Stage: Built from ultralight, ultra-strong technopolymer for durability and a balanced breathing feel.
- Vortex Assisted Design (VAD): Curved bypass tube creates a vortex and low-pressure center that aids diaphragm movement for sensitive, natural breathing at any diving depth.
- Large Purge Button: Sized for easy operation even when wearing thick gloves.
- Travel-Friendly Build: Lightweight technopolymer second stage resists corrosion and is intended for comfort during extended dives.
- Connection Options: Available with a DIN or INT (Yoke) regulator connection.
- Color: Available in Black.
| Brand | Mares |
| Model | Dual 2S |
| First Stage | 2S piston |
| Second Stage Material | Ultralight technopolymer |
| Finish | Sandblasted |
| HP Ports | 1 (7/16 in UNF) |
| LP Ports | 4 (3/8 in UNF) |
| First Stage Weight (INT) | 608 g / 21.4 oz |
| First Stage Weight (DIN) | 440 g / 15.5 oz |
| Second Stage Weight | 182 g / 6.4 oz |
| Total Weight (INT) | 921 g / 32.5 oz |
| Total Weight (DIN) | 753 g / 26.6 oz |
| Hose | Superflex, 75 cm |
| Connection Type | DIN or INT (Yoke) |
| Color | Black |
⚠️ WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, visit www.P65Warnings.ca.gov.
Frequently Asked Questions
How often does a scuba regulator need servicing?
Follow the interval in your regulator's manual, since manufacturers commonly specify an annual inspection or a set number of dives and many warranties depend on it. A regulator is life-support equipment, so service belongs with a factory-trained technician rather than being attempted at home. Have it looked at sooner than scheduled if you notice increased breathing effort, free-flow, bubbles, or water in the second stage.
How do I rinse and care for a regulator after diving?
Make sure the dust cap is dry and firmly seated over the first-stage inlet before the regulator goes anywhere near water, because water inside the first stage is the leading cause of internal corrosion. Rinse in fresh water without pressing the purge button, since purging while depressurized can draw water back into the second stage. Shake out the water and hang it to dry with the hoses in wide, gentle loops rather than tight bends.
Can I fly with a scuba regulator?
Regulators travel well and are usually best carried in hand luggage where they will not be crushed or lost. A regulator holds no gas of its own, so there is nothing inherently problematic about it on an aircraft, though the airline and security screeners always have the final say. Pack it dry with the dust cap in place, in a padded regulator bag or wrapped in soft gear.
Can I use my regulator with nitrox?
Many modern regulators are supplied as suitable for nitrox mixes up to 40 percent oxygen, which is the widely used recreational industry standard, while anything above that requires dedicated oxygen-clean equipment and procedures. Confirm what your specific regulator's manual states, and follow your nitrox training and your fill station's requirements. Never assume a regulator is oxygen-service clean simply because it looks clean or is new.
What is the difference between DIN and yoke regulators?
A yoke (A-clamp) fitting clamps over the tank valve and is the most common connection across much of the recreational world, while a DIN fitting screws into the valve and is standard in much of Europe and in technical diving. DIN captures the o-ring inside the threads, which many divers consider more secure, but yoke is often what rental cylinders provide. Adapters exist in both directions, so check what is used where you dive before deciding.
What is the octopus regulator for?
The octopus is your backup second stage, carried so you can share air with a buddy who is out of gas, or breathe from it yourself if your primary fails or free-flows. It is normally on a longer, brightly colored hose so it is easy to find and hand over under stress. Secure it in the triangle between your chin and the bottom of your rib cage so it is instantly accessible and not dragging through sand or coral.
How should I store a regulator between dive trips?
Store it fully dry, out of sunlight, with the dust cap in place and the hoses in wide loops rather than tightly coiled. Avoid hanging it by the second stages for long periods, which stresses the hose fittings; laying it flat in a padded bag or hanging it by the first stage is kinder. If it has sat unused for a long stretch, have it checked before your next trip rather than assuming it is ready to dive.
What does the RFID chip holder on the Mares Dual 2S first stage do?
The 2S first stage includes a dedicated RFID chip holder that supports tracking the regulator's service history.
Is the Mares Dual 2S available in both DIN and Yoke versions?
Yes. The Dual 2S is offered with a connection selector for DIN or INT (Yoke), listed as SKU 416275DINBK for the DIN version and SKU 416275INTBK for the Yoke version, both in Black, so you can match the fitting to your tank valve.
How heavy is the Mares Dual 2S regulator set?
Total weight is 921 g (32.5 oz) for the INT (Yoke) version and 753 g (26.6 oz) for the DIN version. The first stage alone weighs 608 g (21.4 oz) INT or 440 g (15.5 oz) DIN, and the second stage weighs 182 g (6.4 oz).
What hose does the Mares Dual 2S come with?
The Dual 2S uses a Superflex hose measuring 75 cm in length, connected to the second stage. The first stage has 1 HP port (7/16 in UNF) and 4 LP ports (3/8 in UNF).






















