Atomic Aquatics Z3, Z2 Regulator First Stage
In stock — ships from Irvine, CA
This item is currently on backorder. Order now to reserve yours, and we will ship it as soon as it is back in stock.
Atomic Aquatics Z3, Z2 Regulator First Stage - YOKE is backordered and will ship as soon as it is back in stock.
Pickup available at In Store
Usually ready in 2 hours
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Save with Open Box or Used Purchase
Product Information
The Atomic Aquatics Z3, Z2 Regulator First Stage is a fixed-port, balanced piston first stage built from chrome-plated brass and 316 stainless steel, featuring Atomic's exclusive balanced Jet Seat high-flow piston design with 2 high-pressure ports and 7 low-pressure ports on a fixed cap. It is sold as a first stage only, in DIN or Yoke connection, and is approved for non-dedicated EAN (Nitrox) use up to 40% oxygen.
Who it is for
This first stage suits divers upgrading or rebuilding a regulator setup who want a corrosion-resistant, high-flow piston design for saltwater use. It fits recreational divers who want Nitrox capability built in, as well as those who dive in silty or sandy conditions and want the option of a factory-sealed version for extra protection against environmental intrusion.
Key details
- Design: Balanced Jet Seat high-flow piston, fixed port first stage.
- Material: Chrome-plated brass and 316 stainless steel.
- Ports: 2 fixed high-pressure ports and 7 fixed low-pressure ports.
- Gas compatibility: Approved for non-dedicated EAN use with mixtures up to 40% oxygen.
- Sealing: Optional factory-sealed version protects against silt and sand intrusion.
- Service: Recommended service interval of 2 years or 300 dives.
Compatibility and sizing
This first stage is available in a DIN connection for screw-in tank valves and a Yoke (A-clamp) connection for international tank valves, so choose the version that matches your tank valve or diving region before ordering.
DiveCatalog.com is an authorized Atomic Aquatics dealer and has operated as a dive shop in Irvine, California since 2003. Call 888-701-4017 or start a chat if you need help matching this first stage to your tank valve or existing regulator setup.
- Jet Seat piston design: Atomic Aquatics' exclusive balanced Jet Seat high-flow piston delivers reliable air flow at depth.
- Corrosion-resistant materials: Chrome-plated brass and 316 stainless steel construction resist saltwater corrosion.
- Fixed port configuration: 2 fixed high-pressure ports and 7 fixed low-pressure ports on a fixed cap support flexible hose routing.
- Optional sealed version: A factory-sealed first stage option guards against silt and sand intrusion.
- Nitrox ready: Approved for non-dedicated EAN use with mixtures up to 40% oxygen.
- Connection choice: Offered in DIN or Yoke connection to match different tank valve standards.
- Limited Lifetime Warranty: Metal parts are covered against corrosion, with coverage not contingent on proof of service.
- Service interval: Manufacturer recommends service every 2 years or 300 dives.
| Brand | Atomic Aquatics |
| Model | Z3 / Z2 first stage |
| Product Type | Regulator first stage only |
| First Stage Design | Balanced Jet Seat high-flow piston, fixed port |
| Material | Chrome-plated brass and 316 stainless steel |
| HP Ports | 2 (fixed) |
| LP Ports | 7 (fixed cap) |
| Sealing | Optional factory-sealed version available |
| Gas Compatibility | Approved for non-dedicated EAN use up to 40% oxygen |
| Connection | DIN or Yoke (choose variant) |
| Recommended Service Interval | 2 years or 300 dives |
| Warranty | Limited Lifetime Warranty on metal parts against corrosion |
⚠️ WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, visit www.P65Warnings.ca.gov.
Frequently Asked Questions
How often does a scuba regulator need servicing?
Follow the interval in your regulator's manual, since manufacturers commonly specify an annual inspection or a set number of dives and many warranties depend on it. A regulator is life-support equipment, so service belongs with a factory-trained technician rather than being attempted at home. Have it looked at sooner than scheduled if you notice increased breathing effort, free-flow, bubbles, or water in the second stage.
How do I rinse and care for a regulator after diving?
Make sure the dust cap is dry and firmly seated over the first-stage inlet before the regulator goes anywhere near water, because water inside the first stage is the leading cause of internal corrosion. Rinse in fresh water without pressing the purge button, since purging while depressurized can draw water back into the second stage. Shake out the water and hang it to dry with the hoses in wide, gentle loops rather than tight bends.
Can I fly with a scuba regulator?
Regulators travel well and are usually best carried in hand luggage where they will not be crushed or lost. A regulator holds no gas of its own, so there is nothing inherently problematic about it on an aircraft, though the airline and security screeners always have the final say. Pack it dry with the dust cap in place, in a padded regulator bag or wrapped in soft gear.
Can I use my regulator with nitrox?
Many modern regulators are supplied as suitable for nitrox mixes up to 40 percent oxygen, which is the widely used recreational industry standard, while anything above that requires dedicated oxygen-clean equipment and procedures. Confirm what your specific regulator's manual states, and follow your nitrox training and your fill station's requirements. Never assume a regulator is oxygen-service clean simply because it looks clean or is new.
What is the difference between DIN and yoke regulators?
A yoke (A-clamp) fitting clamps over the tank valve and is the most common connection across much of the recreational world, while a DIN fitting screws into the valve and is standard in much of Europe and in technical diving. DIN captures the o-ring inside the threads, which many divers consider more secure, but yoke is often what rental cylinders provide. Adapters exist in both directions, so check what is used where you dive before deciding.
What is the octopus regulator for?
The octopus is your backup second stage, carried so you can share air with a buddy who is out of gas, or breathe from it yourself if your primary fails or free-flows. It is normally on a longer, brightly colored hose so it is easy to find and hand over under stress. Secure it in the triangle between your chin and the bottom of your rib cage so it is instantly accessible and not dragging through sand or coral.
How should I store a regulator between dive trips?
Store it fully dry, out of sunlight, with the dust cap in place and the hoses in wide loops rather than tightly coiled. Avoid hanging it by the second stages for long periods, which stresses the hose fittings; laying it flat in a padded bag or hanging it by the first stage is kinder. If it has sat unused for a long stretch, have it checked before your next trip rather than assuming it is ready to dive.
How many ports does the Atomic Aquatics Z3/Z2 first stage have?
It has 2 fixed high-pressure ports and 7 fixed low-pressure ports on a fixed cap, supporting flexible hose routing.
How often should this first stage be serviced?
Atomic Aquatics recommends servicing every 2 years or 300 dives, whichever comes first. The Limited Lifetime Warranty on metal parts against corrosion is not contingent on proof of service, but regular service by a trained technician keeps the regulator performing safely.
Does this listing include a second stage or just the first stage?
This listing is for the first stage only, sold separately from any second stage. It is available with either a DIN or Yoke connection so it can be paired with a compatible Atomic Aquatics second stage or used to rebuild an existing setup.
What warranty comes with the Atomic Aquatics Z3/Z2 first stage?
It carries a Limited Lifetime Warranty covering the metal parts against corrosion. Coverage is not contingent on proof of service, though following the recommended 2-year or 300-dive service interval is still advised for reliable performance.