Mares 26XR with HR XR Regulator Line DIN
In stock — ships from Irvine, CA
This item is currently on backorder. Order now to reserve yours, and we will ship it as soon as it is back in stock.
Mares 26XR with HR XR Regulator Line DIN is backordered and will ship as soon as it is back in stock.
Pickup available at In Store
Usually ready in 2 hours
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Save with a package
Ready-made packages that include this item
Save $323.32 (19% off)
Product Information
The Mares 26XR-HR (SKU 416423BK-NR300) is a first and second stage regulator set from the Mares XR technical-diving line, built around the 26XR first stage and the HR second stage. The first stage's design is suited to single-cylinder or stage-cylinder configurations with snag-free hose positioning, and the set uses a G5/8 DIN 300 bar connection.
Who it is for
This set is built for technical divers running single-cylinder or stage-cylinder setups, and it belongs to the Mares XR regulator line, which Mares positions for twinset, sidemount, and stage diving applications where hose routing and port placement matter.
Key details
- First stage: 26XR, sealed, with AST (Auto Sealing Technology) keeping the first stage dry when disconnected from the tank, and a TBP Dry Kit for environmental sealing.
- Ports: 2 HP ports (7/16 in UNF) and 4 radial plus 1 vertical LP port (3/8 in UNF), with Natural DFC on all LP ports.
- Weights: first stage 683 g (24.0 oz) in the DIN 300 configuration; second stage 220 g (7.7 oz).
- Second stage: HR, ultralight technopolymer case, with Adjustable Breathing Comfort and the V.A.D. System for inhalation control, plus an oversized purge button and a premium rubber LP hose.
- Connection: G5/8, 300 bar DIN. Per Mares' listing for this SKU, the set is not nitrox-rated (Nitrox Compatible: NR).
- Color: Black.
DiveCatalog.com is an authorized Mares dealer and a dive shop in Irvine, California, serving divers since 2003. Call or chat with us if you have questions about fit, port configuration, or compatibility with your current setup.
- Adjustable Breathing Comfort: Lets the diver customize inhalation effort on the HR second stage.
- V.A.D. System: Uses a curved bypass to provide natural, high gas flow at any depth.
- Ultralight technopolymer case: A simple, high-performance second-stage case built to reduce weight.
- PAD (Pneumatically Assisted Design): Adds comfort and reduces effort during the inhalation phase.
- Oversized purge button: Sized for easy operation, including with thick dive gloves.
- Premium rubber LP hose: Resists cuts, abrasion, bursting, and UV damage.
- Natural DFC on all LP ports: Maintains high airflow on the first stage regardless of depth.
- TBP Dry Kit: Environmentally sealed first stage for reliability in cold water.
- AST (Auto Sealing Technology): Automatically keeps the first stage dry and protected from water entry when disconnected from the tank.
- Advanced port routing: 4 radial LP ports, 1 vertical LP port, and 2 symmetrical, pre-oriented HP ports for hose positioning.
- Single or stage-cylinder design: The 26XR first stage is suited to single-cylinder or stage-cylinder configurations with snag-free hose positioning.
- G5/8 DIN connection: 300 bar DIN fitting.
| Brand | Mares |
| Model | 26XR with HR second stage, XR Line |
| SKU | 416423BK-NR300 |
| Connection | DIN 300 (G5/8) |
| First Stage | 26XR, sealed, for single-cylinder or stage-cylinder configurations |
| Second Stage | HR, ultralight technopolymer |
| HP Ports | 2 (7/16 in UNF) |
| LP Ports | 4 radial plus 1 vertical (3/8 in UNF), Natural DFC |
| First Stage Weight | 683 g / 24.0 oz (DIN 300) |
| Second Stage Weight | 220 g / 7.7 oz |
| Gauge Pressure | 300 bar |
| Nitrox Compatible | No (NR) |
| Color | Black |
⚠️ WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, visit www.P65Warnings.ca.gov.
Frequently Asked Questions
How often does a scuba regulator need servicing?
Follow the interval in your regulator's manual, since manufacturers commonly specify an annual inspection or a set number of dives and many warranties depend on it. A regulator is life-support equipment, so service belongs with a factory-trained technician rather than being attempted at home. Have it looked at sooner than scheduled if you notice increased breathing effort, free-flow, bubbles, or water in the second stage.
How do I rinse and care for a regulator after diving?
Make sure the dust cap is dry and firmly seated over the first-stage inlet before the regulator goes anywhere near water, because water inside the first stage is the leading cause of internal corrosion. Rinse in fresh water without pressing the purge button, since purging while depressurized can draw water back into the second stage. Shake out the water and hang it to dry with the hoses in wide, gentle loops rather than tight bends.
Can I fly with a scuba regulator?
Regulators travel well and are usually best carried in hand luggage where they will not be crushed or lost. A regulator holds no gas of its own, so there is nothing inherently problematic about it on an aircraft, though the airline and security screeners always have the final say. Pack it dry with the dust cap in place, in a padded regulator bag or wrapped in soft gear.
Can I use my regulator with nitrox?
Many modern regulators are supplied as suitable for nitrox mixes up to 40 percent oxygen, which is the widely used recreational industry standard, while anything above that requires dedicated oxygen-clean equipment and procedures. Confirm what your specific regulator's manual states, and follow your nitrox training and your fill station's requirements. Never assume a regulator is oxygen-service clean simply because it looks clean or is new.
What is the difference between DIN and yoke regulators?
A yoke (A-clamp) fitting clamps over the tank valve and is the most common connection across much of the recreational world, while a DIN fitting screws into the valve and is standard in much of Europe and in technical diving. DIN captures the o-ring inside the threads, which many divers consider more secure, but yoke is often what rental cylinders provide. Adapters exist in both directions, so check what is used where you dive before deciding.
What is the octopus regulator for?
The octopus is your backup second stage, carried so you can share air with a buddy who is out of gas, or breathe from it yourself if your primary fails or free-flows. It is normally on a longer, brightly colored hose so it is easy to find and hand over under stress. Secure it in the triangle between your chin and the bottom of your rib cage so it is instantly accessible and not dragging through sand or coral.
How should I store a regulator between dive trips?
Store it fully dry, out of sunlight, with the dust cap in place and the hoses in wide loops rather than tightly coiled. Avoid hanging it by the second stages for long periods, which stresses the hose fittings; laying it flat in a padded bag or hanging it by the first stage is kinder. If it has sat unused for a long stretch, have it checked before your next trip rather than assuming it is ready to dive.
Is the Mares 26XR-HR nitrox compatible?
No. Mares lists this SKU (416423BK-NR300) as Nitrox Compatible: NR, meaning it is not rated for nitrox mixes.
What cylinder configurations does the Mares 26XR first stage support?
The 26XR first stage is designed for single-cylinder or stage-cylinder configurations, with a design intended to offer snag-free hose positioning. It is part of the Mares XR technical-diving line, which also covers twinset, sidemount, and stage diving applications.
How many ports does the Mares 26XR first stage have?
The 26XR first stage has 2 HP ports (7/16 in UNF) and 5 LP ports total: 4 radial and 1 vertical (3/8 in UNF), each fitted with Natural DFC to maintain airflow regardless of depth.












