Mares Ultra 62X Dive Regulator
In stock — ships from Irvine, CA
This item is currently on backorder. Order now to reserve yours, and we will ship it as soon as it is back in stock.
Mares Ultra 62X Dive Regulator - DIN is backordered and will ship as soon as it is back in stock.
Pickup currently unavailable at In Store
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Save with a package
Ready-made packages that include this item
Save $255.82 (20% off)
Product Information
The Mares Ultra 62X Dive Regulator is a balanced diaphragm first stage and second stage set built from ultralight technopolymer, with a second stage weight of 190 g and a first stage weight of 742 g on the INT (Yoke) version or 525 g on the DIN 300 version.
Who it is for
This regulator suits scuba divers who want a compact, lightweight set for everyday recreational dives and for cold-water conditions, since the first stage is EN 250 cold-water certified. The second stage's Twin Power System lets a diver choose between natural breathing resistance and assisted breathing with increased air flow, and the wide, pivoting purge button is sized to operate even with thick gloves, which matters for divers working in a drysuit or thick gloves setup.
Key details
The first stage is a balanced diaphragm design made of ultralight technopolymer, with AST (Auto Sealing Technology) to help keep the first stage dry, a DFC LP port for high air flow at any depth, and pre-oriented LP and HP ports. It has 2 HP ports (7/16 in UNF) and 4 LP ports (3/8 in UNF). The second stage is also built in ultralight, durable technopolymer and connects via a lightweight Superflex hose. Total assembled weight is 1,068 g on the INT (Yoke) configuration and 851 g on the DIN 300 configuration.
Compatibility and sizing
The Ultra 62X is offered in two connection types: DIN and INT (Yoke), so choose the version that matches your tank valve.
DiveCatalog.com is an authorized Mares dealer and a dive shop in Irvine, California, open since 2003. Call 888-701-4017 or start a chat with our team if you have questions about DIN versus Yoke fit or compatibility with your current setup.
- Twin Power System: Lets divers choose between natural breathing and assisted breathing with increased air flow.
- Second stage material: Ultralight, durable technopolymer body.
- Purge button: Wide, pivoting purge button that is easy to use even with thick gloves.
- Hose: Lightweight Superflex hose for comfort during use.
- First stage design: Balanced diaphragm in a compact, lightweight build.
- AST: Auto Sealing Technology for a dry first stage.
- DFC LP port: Delivers high air flow at any depth.
- Ports: 2 HP ports (7/16 in UNF) and 4 LP ports (3/8 in UNF), pre-oriented for hose routing.
- Certification: EN 250 cold-water certified.
- Connection options: Available in DIN or INT (Yoke) fitting.
- Weight: Second stage weighs 190 g; first stage weighs 742 g (INT) or 525 g (DIN 300).
| Brand | Mares |
| Model | Ultra 62X |
| Connection Type | DIN or INT (Yoke) |
| First Stage | Balanced diaphragm |
| First Stage Material | Ultralight technopolymer |
| Second Stage Material | Ultralight technopolymer |
| HP Ports | 2 (7/16 in UNF) |
| LP Ports | 4 (3/8 in UNF) |
| First Stage Weight | 742 g / 26.2 oz (INT); 525 g / 18.5 oz (DIN 300) |
| Second Stage Weight | 190 g / 6.7 oz |
| Total Weight | 1,068 g / 37.7 oz (INT); 851 g / 30 oz (DIN 300) |
| Cold Water Certification | EN 250 |
⚠️ WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, visit www.P65Warnings.ca.gov.
Frequently Asked Questions
How often does a scuba regulator need servicing?
Follow the interval in your regulator's manual, since manufacturers commonly specify an annual inspection or a set number of dives and many warranties depend on it. A regulator is life-support equipment, so service belongs with a factory-trained technician rather than being attempted at home. Have it looked at sooner than scheduled if you notice increased breathing effort, free-flow, bubbles, or water in the second stage.
How do I rinse and care for a regulator after diving?
Make sure the dust cap is dry and firmly seated over the first-stage inlet before the regulator goes anywhere near water, because water inside the first stage is the leading cause of internal corrosion. Rinse in fresh water without pressing the purge button, since purging while depressurized can draw water back into the second stage. Shake out the water and hang it to dry with the hoses in wide, gentle loops rather than tight bends.
Can I fly with a scuba regulator?
Regulators travel well and are usually best carried in hand luggage where they will not be crushed or lost. A regulator holds no gas of its own, so there is nothing inherently problematic about it on an aircraft, though the airline and security screeners always have the final say. Pack it dry with the dust cap in place, in a padded regulator bag or wrapped in soft gear.
Can I use my regulator with nitrox?
Many modern regulators are supplied as suitable for nitrox mixes up to 40 percent oxygen, which is the widely used recreational industry standard, while anything above that requires dedicated oxygen-clean equipment and procedures. Confirm what your specific regulator's manual states, and follow your nitrox training and your fill station's requirements. Never assume a regulator is oxygen-service clean simply because it looks clean or is new.
What is the difference between DIN and yoke regulators?
A yoke (A-clamp) fitting clamps over the tank valve and is the most common connection across much of the recreational world, while a DIN fitting screws into the valve and is standard in much of Europe and in technical diving. DIN captures the o-ring inside the threads, which many divers consider more secure, but yoke is often what rental cylinders provide. Adapters exist in both directions, so check what is used where you dive before deciding.
What is the octopus regulator for?
The octopus is your backup second stage, carried so you can share air with a buddy who is out of gas, or breathe from it yourself if your primary fails or free-flows. It is normally on a longer, brightly colored hose so it is easy to find and hand over under stress. Secure it in the triangle between your chin and the bottom of your rib cage so it is instantly accessible and not dragging through sand or coral.
How should I store a regulator between dive trips?
Store it fully dry, out of sunlight, with the dust cap in place and the hoses in wide loops rather than tightly coiled. Avoid hanging it by the second stages for long periods, which stresses the hose fittings; laying it flat in a padded bag or hanging it by the first stage is kinder. If it has sat unused for a long stretch, have it checked before your next trip rather than assuming it is ready to dive.
What does AST mean on the Mares Ultra 62X first stage?
AST stands for Auto Sealing Technology, a feature on the Ultra 62X's balanced diaphragm first stage that helps keep the internal mechanism dry. It is built into the first stage alongside the DFC LP port and pre-oriented LP and HP ports, all part of the regulator's compact, lightweight diaphragm design.
How much does the Mares Ultra 62X weigh with DIN versus INT?
The first stage weighs 525 g (18.5 oz) in the DIN 300 version versus 742 g (26.2 oz) in the INT (Yoke) version. The second stage weighs 190 g (6.7 oz) with either connection. Listed total weight is 851 g for DIN 300 and 1,068 g for INT.
What is the Twin Power System on the Ultra 62X second stage?
The Twin Power System is a setting on the Ultra 62X second stage that lets a diver choose between natural breathing resistance and assisted breathing with increased air flow. The second stage body is made of ultralight, durable technopolymer and uses a wide, pivoting purge button designed to work even with thick gloves.
How many low pressure and high pressure ports does the Ultra 62X first stage have?
The Ultra 62X first stage has 4 low pressure (LP) ports sized 3/8 in UNF and 2 high pressure (HP) ports sized 7/16 in UNF. The ports are pre-oriented, and the LP ports include a DFC port rated for high air flow at any depth.





















