Product Information
The Sherwood Magnum Pro Regulator is a first- and second-stage scuba regulator set built on Sherwood's 9000 Series first stage with Air-Assisted Depth-Compensation (A2-DC) balanced piston design, paired with a pneumatically balanced second stage that includes a Venturi flow control switch. It is offered in a Yoke (A-clamp) connection as MPN SRB9350 and in a DIN connection as MPN SRB9350D-CE.
Who it is for
This regulator suits recreational divers who want a dependable, easy-breathing primary regulator for warm to temperate water diving, since the Magnum Pro is suitable for water temperatures warmer than 50 degrees F (10 degrees C). Its flow control switch lets a diver dial out the Venturi effect at the surface or in shallow water, then switch it back on at depth, which makes it practical for divers who move between boat entries, shore dives and deeper descents on the same day.
Key details
- 9000 Series first stage with A2-DC balanced, environmentally sealed and dry design that is flow by piston
- Four LP ports and two HP ports on the first stage for accessory hoses and gauges
- Pneumatically balanced second stage delivers consistent air delivery whether the tank reads 3,000 psi or 500 psi
- Venturi switch for performance adjustment at the surface or at depth
- Single valve tube construction creates a precise channel for valve operation
- Large co-molded mouthpiece uses two different silicone compounds and colors to reduce jaw fatigue
Compatibility and sizing
Choose SRB9350 for a standard Yoke (A-clamp) tank valve or SRB9350D-CE for a DIN valve connection, depending on the tank valve fitting used at your local dive sites or on your own cylinders.
DiveCatalog.com is an authorized Sherwood dealer and has operated as a dive shop in Irvine, California since 2003. Call 888-701-4017 or start a chat if you need help confirming fit, connection type or compatibility with your current setup.
- 9000 Series first stage: Uses a patented A2-DC (Air-Assisted Depth-Compensation) balanced piston design.
- Environmentally sealed and dry: Minimizes corrosion to extend regulator performance over time.
- Flow by piston: First stage design that supports the A2-DC balanced regulator system.
- Four LP ports and two HP ports: Gives room for an octopus, BCD inflator hose, SPG and other accessories.
- Pneumatically balanced second stage: Delivers the same amount of air whether the tank is at 3,000 psi or 500 psi.
- Venturi switch: Lets a diver adjust performance at the surface or at depth for a more stable breathe.
- Single valve tube construction: Creates a precise channel so the valve operates consistently.
- Co-molded mouthpiece: Large mouthpiece made from two different silicone compounds and colors to reduce jaw fatigue.
- Water temperature suitability: Rated for water warmer than 50 degrees F (10 degrees C).
- Connection options: Available as Yoke (SRB9350) or DIN (SRB9350D-CE).
| Brand | Sherwood |
| Product Type | Regulators, 1st and 2nd Stage Set |
| MPN (Yoke) | SRB9350 |
| MPN (DIN) | SRB9350D-CE |
| Connection Type | Yoke or DIN |
| 1st Stage Series | 9000 Series |
| 1st Stage Ports | Four LP ports and two HP ports |
| 1st Stage Design | A2-DC balanced, flow by piston, environmentally sealed and dry |
| 2nd Stage Balance | Pneumatically balanced |
| Venturi Control | Adjustable Venturi switch |
| Valve Construction | Single valve tube |
| Mouthpiece | Co-molded, two silicone compounds and colors |
| Water Temperature Suitability | Above 50 degrees F (10 degrees C) |
⚠️ WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, visit www.P65Warnings.ca.gov.
Frequently Asked Questions
How often does a scuba regulator need servicing?
Follow the interval in your regulator's manual, since manufacturers commonly specify an annual inspection or a set number of dives and many warranties depend on it. A regulator is life-support equipment, so service belongs with a factory-trained technician rather than being attempted at home. Have it looked at sooner than scheduled if you notice increased breathing effort, free-flow, bubbles, or water in the second stage.
How do I rinse and care for a regulator after diving?
Make sure the dust cap is dry and firmly seated over the first-stage inlet before the regulator goes anywhere near water, because water inside the first stage is the leading cause of internal corrosion. Rinse in fresh water without pressing the purge button, since purging while depressurized can draw water back into the second stage. Shake out the water and hang it to dry with the hoses in wide, gentle loops rather than tight bends.
Can I fly with a scuba regulator?
Regulators travel well and are usually best carried in hand luggage where they will not be crushed or lost. A regulator holds no gas of its own, so there is nothing inherently problematic about it on an aircraft, though the airline and security screeners always have the final say. Pack it dry with the dust cap in place, in a padded regulator bag or wrapped in soft gear.
Can I use my regulator with nitrox?
Many modern regulators are supplied as suitable for nitrox mixes up to 40 percent oxygen, which is the widely used recreational industry standard, while anything above that requires dedicated oxygen-clean equipment and procedures. Confirm what your specific regulator's manual states, and follow your nitrox training and your fill station's requirements. Never assume a regulator is oxygen-service clean simply because it looks clean or is new.
What is the difference between DIN and yoke regulators?
A yoke (A-clamp) fitting clamps over the tank valve and is the most common connection across much of the recreational world, while a DIN fitting screws into the valve and is standard in much of Europe and in technical diving. DIN captures the o-ring inside the threads, which many divers consider more secure, but yoke is often what rental cylinders provide. Adapters exist in both directions, so check what is used where you dive before deciding.
What is the octopus regulator for?
The octopus is your backup second stage, carried so you can share air with a buddy who is out of gas, or breathe from it yourself if your primary fails or free-flows. It is normally on a longer, brightly colored hose so it is easy to find and hand over under stress. Secure it in the triangle between your chin and the bottom of your rib cage so it is instantly accessible and not dragging through sand or coral.
How should I store a regulator between dive trips?
Store it fully dry, out of sunlight, with the dust cap in place and the hoses in wide loops rather than tightly coiled. Avoid hanging it by the second stages for long periods, which stresses the hose fittings; laying it flat in a padded bag or hanging it by the first stage is kinder. If it has sat unused for a long stretch, have it checked before your next trip rather than assuming it is ready to dive.
What connection types does the Sherwood Magnum Pro regulator come in?
The Magnum Pro is available as SRB9350 with a Yoke (A-clamp) connection or as SRB9350D-CE with a DIN connection. Pick the version that matches your tank valve or the valve style most common at the sites and shops where you dive.
What water temperatures is the Sherwood Magnum Pro rated for?
The Magnum Pro is listed as suitable for water temperatures warmer than 50 degrees F (10 degrees C). It is best suited to warm and temperate water diving rather than cold water diving below that threshold.
What is the Venturi switch on the Magnum Pro used for?
The Venturi switch lets a diver switch off the Venturi effect at the surface or in shallow water for better manageability, then switch it on at depth.
How many ports does the Magnum Pro first stage have?
The 9000 Series first stage on the Magnum Pro has four low-pressure (LP) ports and two high-pressure (HP) ports. This gives room to connect accessories such as an octopus second stage, BCD inflator hose, and a submersible pressure gauge.