Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Product Information
The Hollis DCX First Stage Dive Regulator is a high-performance, over-balanced diaphragm first stage built for cold water and technical diving, with 2 HP ports, 5 LP ports, and a durable PVD coating, available in DIN or Yoke configurations.
Who it is for
The DCX suits cold water divers, technical divers running backmounted doubles or sidemount, and recreational divers who want a first stage engineered for extreme conditions rather than casual warm water use. The 5th low pressure port points straight down from the first stage, which simplifies hose routing for doubles and sidemount rigs as well as standard single-tank setups.
Key details
The DCX is based on the Hollis DC1 but is lighter and finished with a PVD (Physical Vapor Deposition) coating described as the most durable finish available. Its over-balanced diaphragm design increases medium pressure gas in the hose at a rate faster than ambient pressure as the diver descends, delivering stronger gas flow at depth. An environmental dry sealing system keeps water, salt, and contaminants out of the main spring chamber and helps prevent ice buildup, and the design is built to the CE standard for coldwater performance. A swivel turret lets you orient the low pressure ports for ideal hose routing.
- Ports: 2 HP ports and 5 LP ports
- Design: over-balanced diaphragm first stage with progressive intermediate pressure increase with depth
- Finish: PVD-coated metal
Compatibility and sizing
The DCX is sold in Yoke configuration (SKU 240.3572) and DIN configuration (SKU 240.3573), so confirm which tank valve connection your cylinders use before ordering.
DiveCatalog.com is an authorized Hollis dealer and a dive shop in Irvine, California, operating since 2003. Call 888-701-4017 or chat with us if you have questions about DIN versus Yoke fit or hose routing for your setup.
- Swivel turret allows for ideal low pressure hose routing.
- Environmental sealing prevents internal corrosion, contaminants, and icing of the first stage.
- CE coldwater rated and built to withstand the rigorous CE standard for coldwater performance.
- Streamlined internal design makes the DCX lighter in weight than previous Hollis first stage designs.
- PVD "industrial" plating is a super hard, highly durable Physical Vapor Deposition coating.
- Over-balanced diaphragm design lets medium pressure gas in the hose increase at a rate faster than ambient as the diver descends, for superior performance at depth.
- 2 HP ports and 5 LP ports are provided for optimum hose routing.
- 5th LP port points directly down from the first stage, allowing easy hose routing for backmounted doubles, sidemount, or recreational diving.
- Environmental dry system keeps water out of the main spring chamber, preventing ice buildup and keeping out salt and contamination.
- Based on the Hollis DC1 but lighter and protected by the PVD coating.
| Design | Over-balanced diaphragm first stage with progressive intermediate pressure increase with depth |
| Ports | 2 HP ports and 5 LP ports |
| Configuration options | DIN or Yoke |
| Finish | PVD (Physical Vapor Deposition) coating |
| Certification | Built to the CE standard for coldwater performance |
| Based on | Hollis DC1, lighter weight with PVD finish |
| MPN | 240.3573 |
| SKU (Yoke) | 240.3572 |
| Barcode (Yoke) | 020545210412 |
| SKU (DIN) | 240.3573 |
| Barcode (DIN) | 020545210429 |
⚠️ WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, visit www.P65Warnings.ca.gov.
Frequently Asked Questions
How often does a scuba regulator need servicing?
Follow the interval in your regulator's manual, since manufacturers commonly specify an annual inspection or a set number of dives and many warranties depend on it. A regulator is life-support equipment, so service belongs with a factory-trained technician rather than being attempted at home. Have it looked at sooner than scheduled if you notice increased breathing effort, free-flow, bubbles, or water in the second stage.
How do I rinse and care for a regulator after diving?
Make sure the dust cap is dry and firmly seated over the first-stage inlet before the regulator goes anywhere near water, because water inside the first stage is the leading cause of internal corrosion. Rinse in fresh water without pressing the purge button, since purging while depressurized can draw water back into the second stage. Shake out the water and hang it to dry with the hoses in wide, gentle loops rather than tight bends.
Can I fly with a scuba regulator?
Regulators travel well and are usually best carried in hand luggage where they will not be crushed or lost. A regulator holds no gas of its own, so there is nothing inherently problematic about it on an aircraft, though the airline and security screeners always have the final say. Pack it dry with the dust cap in place, in a padded regulator bag or wrapped in soft gear.
Can I use my regulator with nitrox?
Many modern regulators are supplied as suitable for nitrox mixes up to 40 percent oxygen, which is the widely used recreational industry standard, while anything above that requires dedicated oxygen-clean equipment and procedures. Confirm what your specific regulator's manual states, and follow your nitrox training and your fill station's requirements. Never assume a regulator is oxygen-service clean simply because it looks clean or is new.
What is the difference between DIN and yoke regulators?
A yoke (A-clamp) fitting clamps over the tank valve and is the most common connection across much of the recreational world, while a DIN fitting screws into the valve and is standard in much of Europe and in technical diving. DIN captures the o-ring inside the threads, which many divers consider more secure, but yoke is often what rental cylinders provide. Adapters exist in both directions, so check what is used where you dive before deciding.
What is the octopus regulator for?
The octopus is your backup second stage, carried so you can share air with a buddy who is out of gas, or breathe from it yourself if your primary fails or free-flows. It is normally on a longer, brightly colored hose so it is easy to find and hand over under stress. Secure it in the triangle between your chin and the bottom of your rib cage so it is instantly accessible and not dragging through sand or coral.
How should I store a regulator between dive trips?
Store it fully dry, out of sunlight, with the dust cap in place and the hoses in wide loops rather than tightly coiled. Avoid hanging it by the second stages for long periods, which stresses the hose fittings; laying it flat in a padded bag or hanging it by the first stage is kinder. If it has sat unused for a long stretch, have it checked before your next trip rather than assuming it is ready to dive.
What is an over-balanced first stage regulator?
An over-balanced first stage, like the Hollis DCX, increases the medium pressure gas in the hose at a rate faster than ambient pressure as the diver descends. As the diver descends, this over-balancing delivers superior performance at depth.
How is the Hollis DCX different from the Hollis DC1?
The DCX is based on the Hollis DC1 but is lighter and finished with a PVD (Physical Vapor Deposition) coating, described as the most durable coating available, instead of a traditional finish. The DCX keeps the over-balanced diaphragm design, 2 HP and 5 LP ports, and a 5th LP port pointing straight down.
Is the Hollis DCX suitable for sidemount or backmounted doubles?
Yes. The DCX has a 5th low pressure port that points directly down from the first stage, which Hollis designed specifically to simplify hose routing for backmounted doubles and sidemount configurations, in addition to standard recreational single-tank setups.
Does the Hollis DCX come in DIN or Yoke, and how do I tell them apart?
The DCX is available in both configurations: Yoke is SKU 240.3572 and DIN is SKU 240.3573. Check your cylinder valve type before ordering, since Yoke clamps over the valve while DIN screws directly into it.