SEAC SET IT500 + OCTO (INCLUDED MATE REG BAG)
SEAC SET IT500 + OCTO (INCLUDED MATE REG BAG) - Black / 300 DIN is backordered and will ship as soon as it is back in stock.
Pickup currently unavailable at In Store
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Product Information
The SEAC SET IT500 + OCTO is a balanced diaphragm first and second stage scuba regulator set paired with the IT500 Octo backup second stage, supplied in a preformed semi-rigid carrying case. The first stage is hot forged and CNC machined with 2 high-pressure and 4 low-pressure ports. The first and second stages are EN250A certified for cold water, and the Octo complies with CE EN 250-2014. The set is available in DIN and INT (Yoke) connections.
Who it is for
This set is for divers who need a complete primary and backup regulator setup that can be configured with a second stage, octopus, pressure gauge, jacket LP hose, dry suit LP hose and transmitter from a single first stage. It suits divers choosing between DIN and INT (Yoke) tank connections and who want a matched Octo and carrying case included with the primary regulator.
Key details
- Balanced diaphragm first stage, hot forged and CNC machined, with a matt chrome finish
- 2 high-pressure ports and 4 low-pressure ports on the first stage
- EN250A certified for cold water (first and second stage); Octo complies with CE EN 250-2014
- Ergonomic knob integrated with the dive/pre-dive lever to regulate breathing effort and the Venturi effect
- Purge button made of soft PU in 2 materials, part of a front shield with a steel ring
- Exhaust deflector geometry directs exhaled bubbles to the sides of the face and helps resist water ingress in side currents
- 2-material LP hose guards sized to help avoid hose kinking
- IT500 Octo has a 1 meter braided hose and its own adjustable Venturi (Dive/Pre-Dive) control
- Available in DIN and INT (Yoke) versions; Made in Italy
Compatibility and sizing
The first stage's HP and LP outlets are ergonomically pre-oriented for a second stage, octopus, pressure gauge, jacket LP hose, dry suit LP hose and transmitter, so the set can be configured for different rigging setups. It is offered in Black with a choice of 300 DIN or 230 INT connection options.
What's in the box
- SEAC IT500 first/second stage regulator
- IT500 Octo backup second stage
- Preformed semi-rigid carrying case with ultra-resistant fabric finish, handle and internal conformers
DiveCatalog.com is an authorized SEAC dealer and a dive shop in Irvine, California, open since 2003. Call 888-701-4017 or chat with us if you have questions about DIN versus INT fit or configuring this set for your setup.
- Balanced diaphragm first stage hot forged and CNC machined, available in DIN and INT versions.
- 2 HP and 4 LP ports ergonomically pre-oriented for a second stage, octopus, pressure gauge, jacket LP hose, dry suit LP hose and transmitter.
- EN250A certified for cold water on the first and second stage; the IT500 Octo complies with CE EN 250-2014.
- Integrated dive/pre-dive knob regulates breathing effort and optimizes the Venturi effect to reduce free-flow risk when the regulator is left in water.
- 2-material soft PU purge button set into a front shield with a steel ring, usable with thick gloves.
- Front and side openings deflect currents to help resist free-flow.
- Exhaust deflector with a dedicated geometry directs exhaled bubbles to the sides of the face and resists water ingress in side currents.
- 2-material LP hose guards sized in diameter and length to help avoid hose kinking.
- IT500 Octo backup second stage included, with a 1 meter braided hose and its own adjustable Venturi control.
- Matt chrome finish on the first stage.
- Includes a preformed semi-rigid carrying case with an ultra-resistant fabric finish, handle and internal conformers.
| First stage type | Balanced diaphragm |
| First stage construction | Hot forged and CNC machined |
| First stage finish | Matt chrome |
| High-pressure ports | 2 |
| Low-pressure ports | 4 |
| Connection type | DIN and INT (Yoke) versions available |
| First/second stage certification | EN250A (cold water) |
| Octo certification | CE EN 250-2014 |
| Octo hose length | 1 meter |
| Octo hose coating | Braided |
| Color | Black |
| Connection options | 300 DIN, 230 INT |
| Country of manufacture | Italy |
| Included case | Preformed semi-rigid carrying case |
- SEAC IT500 first/second stage regulator
- IT500 Octo backup second stage
- Preformed semi-rigid carrying case with ultra-resistant fabric finish, handle and internal conformers
⚠️ WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, visit www.P65Warnings.ca.gov.
Frequently Asked Questions
How often does a scuba regulator need servicing?
Follow the interval in your regulator's manual, since manufacturers commonly specify an annual inspection or a set number of dives and many warranties depend on it. A regulator is life-support equipment, so service belongs with a factory-trained technician rather than being attempted at home. Have it looked at sooner than scheduled if you notice increased breathing effort, free-flow, bubbles, or water in the second stage.
How do I rinse and care for a regulator after diving?
Make sure the dust cap is dry and firmly seated over the first-stage inlet before the regulator goes anywhere near water, because water inside the first stage is the leading cause of internal corrosion. Rinse in fresh water without pressing the purge button, since purging while depressurized can draw water back into the second stage. Shake out the water and hang it to dry with the hoses in wide, gentle loops rather than tight bends.
Can I fly with a scuba regulator?
Regulators travel well and are usually best carried in hand luggage where they will not be crushed or lost. A regulator holds no gas of its own, so there is nothing inherently problematic about it on an aircraft, though the airline and security screeners always have the final say. Pack it dry with the dust cap in place, in a padded regulator bag or wrapped in soft gear.
Can I use my regulator with nitrox?
Many modern regulators are supplied as suitable for nitrox mixes up to 40 percent oxygen, which is the widely used recreational industry standard, while anything above that requires dedicated oxygen-clean equipment and procedures. Confirm what your specific regulator's manual states, and follow your nitrox training and your fill station's requirements. Never assume a regulator is oxygen-service clean simply because it looks clean or is new.
What is the difference between DIN and yoke regulators?
A yoke (A-clamp) fitting clamps over the tank valve and is the most common connection across much of the recreational world, while a DIN fitting screws into the valve and is standard in much of Europe and in technical diving. DIN captures the o-ring inside the threads, which many divers consider more secure, but yoke is often what rental cylinders provide. Adapters exist in both directions, so check what is used where you dive before deciding.
What is the octopus regulator for?
The octopus is your backup second stage, carried so you can share air with a buddy who is out of gas, or breathe from it yourself if your primary fails or free-flows. It is normally on a longer, brightly colored hose so it is easy to find and hand over under stress. Secure it in the triangle between your chin and the bottom of your rib cage so it is instantly accessible and not dragging through sand or coral.
How should I store a regulator between dive trips?
Store it fully dry, out of sunlight, with the dust cap in place and the hoses in wide loops rather than tightly coiled. Avoid hanging it by the second stages for long periods, which stresses the hose fittings; laying it flat in a padded bag or hanging it by the first stage is kinder. If it has sat unused for a long stretch, have it checked before your next trip rather than assuming it is ready to dive.
What comes with the SEAC SET IT500 + Octo regulator set?
The set includes the SEAC IT500 first/second stage regulator, the IT500 Octo backup second stage, and a preformed semi-rigid carrying case with an ultra-resistant fabric finish, a handle and internal conformers for protecting the assembly during transport.
Is the SEAC IT500 regulator rated for cold water diving?
Yes. The IT500 first and second stage are EN250A certified for cold water, and the IT500 Octo backup second stage complies with CE EN 250-2014.
How long is the hose on the IT500 Octo second stage?
The IT500 Octo has a 1 meter braided hose, along with its own adjustable Venturi (Dive/Pre-Dive) control and a 2-material whip guard designed for structure and stability.
What can I connect to the SEAC IT500 first stage?
The first stage has 2 high-pressure and 4 low-pressure ports, ergonomically pre-oriented for a second stage, octopus, pressure gauge, jacket LP hose, dry suit LP hose and transmitter, allowing it to be configured for different rigging setups.





















