SEAC SET IT500 ICE + OCTO (INCLUDED MATE REG BAG)
FREE complimentary dive gear with qualifying purchases. Some exclusions may apply. Learn more.
SEAC SET IT500 ICE + OCTO (INCLUDED MATE REG BAG) - Black / 300 DIN is backordered and will ship as soon as it is back in stock.
Pickup currently unavailable at In Store
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Product Information
The SEAC SET IT500 ICE + OCTO is a scuba diving regulator set that pairs the IT500 ICE balanced diaphragm first stage with the IT500 Octo backup second stage, both EN250A certified for cold water and supplied with a MATE reg bag for transport. It is built in Italy with a hot-forged, CNC-machined first stage body, and is available in DIN or INT (yoke) connection.
Who it is for
This set suits divers who want a complete, ready-to-use primary and backup regulator setup in one box rather than buying stages separately. Because the first stage offers dedicated outlets for a jacket LP hose, a dry suit LP hose, a pressure gauge, and a transmitter in addition to the octopus, it works for divers running a BCD, a dry suit, or an air-integrated computer off the same first stage.
Key details
- Balanced diaphragm first stage, hot forged and CNC machined
- 2 high-pressure ports and 4 low-pressure ports on the first stage
- Available in DIN or INT (Yoke) connection
- First and second stage EN250A certified for cold water; Octo complies with CE EN 250-2014
- Ergonomic knob integrated with the dive/pre-dive lever to adjust breathing effort and the Venturi effect
- Large soft-PU purge button on a front shield with a steel ring, usable with thick gloves
- Octo second stage has a 1 meter braided hose and its own adjustable dive/pre-dive Venturi control
Compatibility and sizing
The first stage's outlet layout is pre-oriented for a second stage, octopus, pressure gauge, jacket LP hose, dry suit LP hose, and transmitter, so divers can add a dry suit or an air-integrated transmitter without reconfiguring the first stage. Choose the DIN or INT (Yoke) version to match your tank valve.
What's in the box
- SEAC IT500 ICE first and second stage regulator
- IT500 Octo backup second stage
- MATE reg bag with handle and internal conformers for transport and storage
DiveCatalog.com is an authorized SEAC dealer and a dive shop in Irvine, California, serving divers since 2003. Call 888-701-4017 or start a chat if you have questions about DIN versus INT fit or matching this set to your dry suit or transmitter.
- Balanced diaphragm first stage: hot forged and CNC machined.
- Port layout: 2 high-pressure ports and 4 low-pressure ports for accessories.
- Cold water certification: first and second stage are EN250A certified; the Octo complies with CE EN 250-2014.
- Connection options: available in DIN and INT (Yoke) versions.
- Ergonomic breathing control: integrated knob with dive/pre-dive lever adjusts breathing effort and Venturi effect to reduce free-flow risk.
- Purge button: generously sized, made of soft PU in two materials, set in a front shield with a steel ring, usable with thick gloves.
- Current deflection: front and side openings and a uniquely shaped exhaust deflector help reduce free-flow and direct exhaled bubbles away from the face.
- Hose guards: two-material LP hose guards sized to avoid kinking.
- Pre-oriented outlets: arranged for second stage, octopus, pressure gauge, jacket LP hose, dry suit LP hose, and transmitter.
- Octo second stage: 1 meter braided hose with its own adjustable dive/pre-dive Venturi control and a two-material whip guard.
- MATE reg bag included: features a handle and internal conformers for transport and storage.
| Brand | SEAC |
| Model | IT500 ICE + Octo |
| First stage type | Balanced diaphragm |
| First stage construction | Hot forged and CNC machined |
| High-pressure ports | 2 |
| Low-pressure ports | 4 |
| Connection type | DIN or INT (Yoke) |
| First stage certification | EN250A (cold water) |
| Octo certification | CE EN 250-2014 |
| Octo hose length | 1 meter |
| Octo hose coating | Braided |
| Octo adjustment | Dive/pre-dive Venturi control |
| Color | Black |
| Included bag | MATE reg bag |
| Country of manufacture | Italy |
- SEAC IT500 ICE first and second stage regulator
- IT500 Octo backup second stage
- MATE reg bag with handle and internal conformers
⚠️ WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, visit www.P65Warnings.ca.gov.
Frequently Asked Questions
How often does a scuba regulator need servicing?
Follow the interval in your regulator's manual, since manufacturers commonly specify an annual inspection or a set number of dives and many warranties depend on it. A regulator is life-support equipment, so service belongs with a factory-trained technician rather than being attempted at home. Have it looked at sooner than scheduled if you notice increased breathing effort, free-flow, bubbles, or water in the second stage.
How do I rinse and care for a regulator after diving?
Make sure the dust cap is dry and firmly seated over the first-stage inlet before the regulator goes anywhere near water, because water inside the first stage is the leading cause of internal corrosion. Rinse in fresh water without pressing the purge button, since purging while depressurized can draw water back into the second stage. Shake out the water and hang it to dry with the hoses in wide, gentle loops rather than tight bends.
Can I fly with a scuba regulator?
Regulators travel well and are usually best carried in hand luggage where they will not be crushed or lost. A regulator holds no gas of its own, so there is nothing inherently problematic about it on an aircraft, though the airline and security screeners always have the final say. Pack it dry with the dust cap in place, in a padded regulator bag or wrapped in soft gear.
Can I use my regulator with nitrox?
Many modern regulators are supplied as suitable for nitrox mixes up to 40 percent oxygen, which is the widely used recreational industry standard, while anything above that requires dedicated oxygen-clean equipment and procedures. Confirm what your specific regulator's manual states, and follow your nitrox training and your fill station's requirements. Never assume a regulator is oxygen-service clean simply because it looks clean or is new.
What is the difference between DIN and yoke regulators?
A yoke (A-clamp) fitting clamps over the tank valve and is the most common connection across much of the recreational world, while a DIN fitting screws into the valve and is standard in much of Europe and in technical diving. DIN captures the o-ring inside the threads, which many divers consider more secure, but yoke is often what rental cylinders provide. Adapters exist in both directions, so check what is used where you dive before deciding.
What is the octopus regulator for?
The octopus is your backup second stage, carried so you can share air with a buddy who is out of gas, or breathe from it yourself if your primary fails or free-flows. It is normally on a longer, brightly colored hose so it is easy to find and hand over under stress. Secure it in the triangle between your chin and the bottom of your rib cage so it is instantly accessible and not dragging through sand or coral.
How should I store a regulator between dive trips?
Store it fully dry, out of sunlight, with the dust cap in place and the hoses in wide loops rather than tightly coiled. Avoid hanging it by the second stages for long periods, which stresses the hose fittings; laying it flat in a padded bag or hanging it by the first stage is kinder. If it has sat unused for a long stretch, have it checked before your next trip rather than assuming it is ready to dive.
Is the SEAC IT500 ICE regulator rated for cold water diving?
Yes. Both the IT500 ICE first and second stage are EN250A certified, which is the cold water rating, and the IT500 Octo backup second stage complies with CE EN 250-2014. This makes the set suitable for divers who need cold water certified life-support equipment.
How many ports does the IT500 first stage have for adding accessories?
The IT500 first stage has 2 high-pressure ports and 4 low-pressure ports. The outlets are pre-oriented for the second stage, the octopus, a pressure gauge, a jacket LP hose, a dry suit LP hose, and a transmitter, so you can build out your full gear configuration from one first stage.
What is included in the SEAC SET IT500 ICE + OCTO MATE bag bundle?
The set includes the SEAC IT500 ICE first and second stage regulator, the IT500 Octo backup second stage, and a MATE reg bag with a handle and internal conformers for carrying and storing the set.
Should I choose the DIN or INT version of the SEAC IT500 ICE set?
Choose the DIN version if your tank valve has a DIN fitting, which screws directly into the valve, or the INT (Yoke) version if your tank uses a standard A-clamp valve. This set is available in both 300 DIN and 230 INT configurations, each in black.





















