SEAC REGULATOR IT500 ICE
FREE complimentary dive gear with qualifying purchases. Some exclusions may apply. Learn more.
SEAC REGULATOR IT500 ICE - Black / 300 DIN is backordered and will ship as soon as it is back in stock.
Pickup currently unavailable at In Store
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Product Information
The SEAC IT500 ICE is a balanced diaphragm first and second stage regulator set engineered for cold-water and sub-zero diving, combining an integrated ICE anti-freeze kit with SEAC's OWS (Optimized Water Strainer) system and EN250A certification. The first stage is hot-forged and CNC-machined with 2 high-pressure ports and 4 low-pressure ports, and the set is available in DIN and INT (Yoke) connection types.
Who it is for
This regulator set is built for divers who need a cold-water-certified setup, from drysuit divers in low temperatures to anyone who wants a first stage with enough pre-oriented ports to configure a second stage, octopus, pressure gauge, and both a jacket LP hose and a drysuit LP hose on the same first stage.
Key details
- Balanced diaphragm first stage, hot-forged and CNC-machined
- 2 high-pressure ports and 4 low-pressure ports, pre-oriented for flexible hose routing
- EN250A certified for cold-water and sub-zero diving
- Integrated ICE anti-freeze kit and OWS (Optimized Water Strainer) system
- Ergonomic adjustment knob integrated with the Dive/Pre-Dive lever
- Large soft PU dual-material purge button, steel-ring front cover, and a bi-material LP hose protector
Compatibility and sizing
The IT500 ICE is offered in a DIN version and an INT (Yoke) version, so choose the connection type that matches your cylinder valve. It is also available in the color Black, and SEAC publishes an IT500 BLACK variant with a full-black finish and the same technical specifications.
What's in the box
- IT500 ICE first and second stage regulator
- Semi-rigid molded carry case with ultra-resistant fabric shell, handle, and internal protective supports
DiveCatalog.com is an authorized SEAC dealer and a dive shop in Irvine, California, serving divers since 2003. Call or chat with us at 888-701-4017 if you have questions about DIN versus INT fit or how this regulator pairs with your current configuration.
- Balanced diaphragm first stage that is hot-forged and CNC-machined for high air flow across depth ranges.
- 2 HP and 4 LP ports pre-oriented on the first stage for flexible hose routing and multiple gear configurations.
- EN250A certified for cold-water and sub-zero diving conditions.
- Integrated ICE anti-freeze kit that supports the EN250A cold-water certification.
- OWS (Optimized Water Strainer) system reduces pressure on the diaphragm and limits unintended air delivery through synergy of front and lateral openings.
- Ergonomic adjustment knob integrated with the Dive/Pre-Dive lever to optimize inhalation effort and the Venturi effect, helping prevent free-flow at the surface or in currents.
- Large soft PU dual-material purge button designed for easy operation with thick gloves.
- Steel-ring front cover that optimizes water flow and helps reduce breathing effort.
- Engineered exhaust tee and deflector that helps prevent water entry during lateral currents and directs exhaust bubbles away from the diver's field of view.
- Bi-material LP hose protector designed to help prevent hose kinking.
- DIN and INT connection types available to match different cylinder valves.
| First stage type | Balanced diaphragm, hot-forged, CNC-machined |
| HP ports | 2 |
| LP ports | 4 |
| Certification | EN250A (cold-water/sub-zero certified) |
| Connection types | DIN and INT (Yoke) |
| Anti-freeze system | Integrated ICE anti-freeze kit |
| Water strainer system | OWS (Optimized Water Strainer) |
| Color option | Black |
| Product type | Regulators, 1st and 2nd stage set |
| Case included | Semi-rigid molded carry case with fabric shell, handle, and internal conformers |
- IT500 ICE first and second stage regulator
- Semi-rigid molded carry case with ultra-resistant fabric shell, handle, and internal protective supports
⚠️ WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, visit www.P65Warnings.ca.gov.
Frequently Asked Questions
How often does a scuba regulator need servicing?
Follow the interval in your regulator's manual, since manufacturers commonly specify an annual inspection or a set number of dives and many warranties depend on it. A regulator is life-support equipment, so service belongs with a factory-trained technician rather than being attempted at home. Have it looked at sooner than scheduled if you notice increased breathing effort, free-flow, bubbles, or water in the second stage.
How do I rinse and care for a regulator after diving?
Make sure the dust cap is dry and firmly seated over the first-stage inlet before the regulator goes anywhere near water, because water inside the first stage is the leading cause of internal corrosion. Rinse in fresh water without pressing the purge button, since purging while depressurized can draw water back into the second stage. Shake out the water and hang it to dry with the hoses in wide, gentle loops rather than tight bends.
Can I fly with a scuba regulator?
Regulators travel well and are usually best carried in hand luggage where they will not be crushed or lost. A regulator holds no gas of its own, so there is nothing inherently problematic about it on an aircraft, though the airline and security screeners always have the final say. Pack it dry with the dust cap in place, in a padded regulator bag or wrapped in soft gear.
Can I use my regulator with nitrox?
Many modern regulators are supplied as suitable for nitrox mixes up to 40 percent oxygen, which is the widely used recreational industry standard, while anything above that requires dedicated oxygen-clean equipment and procedures. Confirm what your specific regulator's manual states, and follow your nitrox training and your fill station's requirements. Never assume a regulator is oxygen-service clean simply because it looks clean or is new.
What is the difference between DIN and yoke regulators?
A yoke (A-clamp) fitting clamps over the tank valve and is the most common connection across much of the recreational world, while a DIN fitting screws into the valve and is standard in much of Europe and in technical diving. DIN captures the o-ring inside the threads, which many divers consider more secure, but yoke is often what rental cylinders provide. Adapters exist in both directions, so check what is used where you dive before deciding.
What is the octopus regulator for?
The octopus is your backup second stage, carried so you can share air with a buddy who is out of gas, or breathe from it yourself if your primary fails or free-flows. It is normally on a longer, brightly colored hose so it is easy to find and hand over under stress. Secure it in the triangle between your chin and the bottom of your rib cage so it is instantly accessible and not dragging through sand or coral.
How should I store a regulator between dive trips?
Store it fully dry, out of sunlight, with the dust cap in place and the hoses in wide loops rather than tightly coiled. Avoid hanging it by the second stages for long periods, which stresses the hose fittings; laying it flat in a padded bag or hanging it by the first stage is kinder. If it has sat unused for a long stretch, have it checked before your next trip rather than assuming it is ready to dive.
What does EN250A certification mean on the SEAC IT500 ICE?
EN250A is the European standard testing for performance in cold water and at sub-zero temperatures. The IT500 ICE meets this certification through its integrated ICE anti-freeze kit, which protects the first stage mechanism so the regulator can be used in cold-water diving conditions.
Should I choose the DIN or INT version of the IT500 ICE?
The IT500 ICE is published in both a DIN version and an INT (Yoke) version, so your choice depends on which connection type your cylinder valve uses. DIN screws into the valve while INT (Yoke) clamps over it; pick the version that matches your tank fitting.
How many hose ports does the IT500 ICE first stage have?
The IT500 ICE first stage has 2 high-pressure ports and 4 low-pressure ports, all pre-oriented for flexible routing. This allows configurations that include a second stage, octopus, pressure gauge, a jacket LP hose, a drysuit LP hose, and a transmitter.
Is the IT500 ICE the same as the IT500 BLACK?
SEAC publishes the IT500 BLACK as a variant with a full-black finish that shares the same technical specifications as the IT500 ICE, including the balanced diaphragm first stage, 2 HP/4 LP ports, and EN250A certification. The difference is the finish color, not the internal mechanism.


















