Aqualung Helix Compact Pro Dive Regulator Black
In stock — ships from Irvine, CA
This item is currently on backorder. Order now to reserve yours, and we will ship it as soon as it is back in stock.
Aqualung Helix Compact Pro Dive Regulator Black - DIN is backordered and will ship as soon as it is back in stock.
Pickup available at In Store
Usually ready in 2 hours
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Save with a package
Ready-made packages that include this item
Save $60.00 (3% off)
Product Information
The Aqua Lung Helix Compact Pro Dive Regulator is a balanced diaphragm regulator set built for divers who want a smaller, lighter balanced diaphragm first stage without giving up sealed internals. It pairs a sealed, environmentally protected first stage carrying 2 HP and 4 MP ports in a "T" layout with a pneumatically balanced second stage rated at 1.35 j/L work of breathing at 50 m, and it is offered in DIN (300 bar) or yoke (232 bar).
Who it is for
This is the Helix Pro for the diver who flies to the dive. The Compact first stage reduces size and weight while keeping the balanced diaphragm design and sealed internals, so packed weight drops and the first stage sits closer to the cylinder valve. Heat exchangers on the second stage resist icing, making it a sensible choice for cold water as well as warm travel destinations, and the in-line venturi knob allows precise adjustments, even with gloves, to prevent free-flowing at the surface.
Key details
- Balanced diaphragm first stage with permanent dry chamber and Auto-Closure Device (ACD) that seals the inlet when the core leaves the valve.
- 2 HP ports (7/16") and 4 MP ports (3/8") oriented in a "T" shape for streamlined hose routing.
- First stage weight 740 g DIN / 525 g yoke; second stage 200 g.
- Pneumatically balanced second stage with balanced downstream valve, in-line venturi knob and a "Mini/Maxi" opening effort adjustment knob.
- Comfo-Bite mouthpiece with palate bridge, lip shield, and a braided hose for flexibility and packing.
- Built on standard Aqua Lung components for straightforward service at your dive shop.
Compatibility and sizing
Choose DIN (SKU RG154003) for screw-in valves and technical cylinders up to 300 bar, or yoke (SKU RG154002) for A-clamp valves up to 232 bar. The 4 MP ports accept an octopus and inflator hoses, and either HP port takes a gauge or transmitter. Finish is black.
DiveCatalog.com is an authorized Aqua Lung dealer and a real dive shop in Irvine, California since 2003. Call 888-701-4017 or start a chat if you want help deciding between DIN and yoke or matching hoses and an octopus to this set.
- Travel-ready first stage Reduced size and weight compared with the Helix Pro first stage, cutting packed weight and sitting closer to the cylinder valve.
- Balanced diaphragm design Sealed internals deliver consistent intermediate pressure as tank pressure and depth change.
- Auto-Closure Device (ACD) Automatically closes the first-stage inlet when the core is removed from the cylinder valve, keeping corrosive water out.
- Permanent dry chamber Environmentally sealed chamber protects internal parts from water and contaminants.
- DIN or yoke Available in yoke (3,300 psi / 232 bar max.) or DIN (4,350 psi / 300 bar max.).
- Port layout 2 HP ports (7/16") and 4 MP ports (3/8") arranged in a "T" shape for streamlined hose positioning and bubbles routed out of your field of view.
- Braided hose Flexible and comfortable, and easy to pack for travel.
- Standard Aqua Lung parts Uses standard Aqua Lung components, so servicing at your local dive shop is straightforward.
- Pneumatically balanced second stage Balanced downstream valve for smooth, easy breathing; 1.35 j/L work of breathing at 50 m, 50 bar, 62.5 l/min.
- Mini/Maxi adjustment knob Increase opening effort to avoid free-flow at the surface, or lower inhalation effort to reduce work of breathing.
- Cover opening channels and heat exchangers Wider cover openings let water pass sideways over the diaphragm to prevent free-flow in current, while heat exchangers resist icing in cold water.
- Comfo-Bite mouthpiece Soft yet sturdy mouthpiece with a palate bridge that reduces jaw fatigue, plus a lip shield.
| Brand | Aqua Lung |
| Model | Helix Compact Pro |
| Type | Regulator set, 1st and 2nd stage |
| First Stage | Balanced diaphragm |
| Connection Options | DIN or Yoke |
| Max Working Pressure | 300 bar / 4,350 psi DIN; 232 bar / 3,300 psi yoke |
| ACD System | Yes |
| Environmental Chamber | Yes (permanent dry chamber) |
| HP Ports | 2 (7/16") |
| MP Ports | 4 (3/8") |
| Port Orientation | "T" shape |
| First Stage Weight | 740 g DIN / 525 g yoke |
| Second Stage | Pneumatically balanced, balanced downstream valve |
| Venturi Vane | Yes (in-line venturi knob) |
| Adjustment Knob | Yes (Mini/Maxi opening effort) |
| Heat Exchangers | Yes |
| Mouthpiece | Comfo-Bite |
| Lip Shield | Yes |
| Hose | Braided |
| Second Stage Weight | 200 g |
| Work of Breathing | 1.35 j/L at 50 m, 50 bar, 62.5 l/min |
| Color | Black |
| SKU | RG154003 (DIN) / RG154002 (Yoke) |
⚠️ WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, visit www.P65Warnings.ca.gov.
Frequently Asked Questions
How often does a scuba regulator need servicing?
Follow the interval in your regulator's manual, since manufacturers commonly specify an annual inspection or a set number of dives and many warranties depend on it. A regulator is life-support equipment, so service belongs with a factory-trained technician rather than being attempted at home. Have it looked at sooner than scheduled if you notice increased breathing effort, free-flow, bubbles, or water in the second stage.
How do I rinse and care for a regulator after diving?
Make sure the dust cap is dry and firmly seated over the first-stage inlet before the regulator goes anywhere near water, because water inside the first stage is the leading cause of internal corrosion. Rinse in fresh water without pressing the purge button, since purging while depressurized can draw water back into the second stage. Shake out the water and hang it to dry with the hoses in wide, gentle loops rather than tight bends.
Can I fly with a scuba regulator?
Regulators travel well and are usually best carried in hand luggage where they will not be crushed or lost. A regulator holds no gas of its own, so there is nothing inherently problematic about it on an aircraft, though the airline and security screeners always have the final say. Pack it dry with the dust cap in place, in a padded regulator bag or wrapped in soft gear.
Can I use my regulator with nitrox?
Many modern regulators are supplied as suitable for nitrox mixes up to 40 percent oxygen, which is the widely used recreational industry standard, while anything above that requires dedicated oxygen-clean equipment and procedures. Confirm what your specific regulator's manual states, and follow your nitrox training and your fill station's requirements. Never assume a regulator is oxygen-service clean simply because it looks clean or is new.
What is the difference between DIN and yoke regulators?
A yoke (A-clamp) fitting clamps over the tank valve and is the most common connection across much of the recreational world, while a DIN fitting screws into the valve and is standard in much of Europe and in technical diving. DIN captures the o-ring inside the threads, which many divers consider more secure, but yoke is often what rental cylinders provide. Adapters exist in both directions, so check what is used where you dive before deciding.
What is the octopus regulator for?
The octopus is your backup second stage, carried so you can share air with a buddy who is out of gas, or breathe from it yourself if your primary fails or free-flows. It is normally on a longer, brightly colored hose so it is easy to find and hand over under stress. Secure it in the triangle between your chin and the bottom of your rib cage so it is instantly accessible and not dragging through sand or coral.
How should I store a regulator between dive trips?
Store it fully dry, out of sunlight, with the dust cap in place and the hoses in wide loops rather than tightly coiled. Avoid hanging it by the second stages for long periods, which stresses the hose fittings; laying it flat in a padded bag or hanging it by the first stage is kinder. If it has sat unused for a long stretch, have it checked before your next trip rather than assuming it is ready to dive.
How is the Helix Compact Pro different from the standard Helix Pro?
The Helix Compact Pro reduces the size and weight of the Helix Pro first stage while keeping the same balanced diaphragm design and sealed internals. The smaller body lowers packed weight for travel and sits closer to the cylinder valve for a tidier profile. It still carries 2 HP ports and 4 MP ports in the "T" layout, and the second stage remains pneumatically balanced with heat exchangers.
Is the Helix Compact Pro suitable for cold water diving?
It is built with cold water features. The second stage uses heat exchangers to resist icing, and the first stage has a permanent dry chamber that keeps water away from the internal parts. The balanced diaphragm design and the Mini/Maxi adjustment knob also let you raise opening effort to stop a free-flow at the surface. Always dive within your training and local cold water practices.
How many hoses can I connect to the first stage?
The first stage has 2 high pressure ports in 7/16" thread and 4 medium pressure ports in 3/8" thread, arranged in a "T" shape for streamlined hose routing. That lets you run a primary second stage, an octopus, a BCD or drysuit inflator, and still have an MP port spare, plus a gauge or air transmitter on either HP port.
What do the two knobs on the second stage do?
The in-line venturi knob prevents free-flowing and allows precise adjustments, even while wearing gloves. The separate Mini/Maxi adjustment knob sets opening effort: raise it to prevent free-flow, lower it underwater to reduce inhalation effort and work of breathing.



























