Seac DX200 Regulator
In stock — ships from Irvine, CA
This item is currently on backorder. Order now to reserve yours, and we will ship it as soon as it is back in stock.
Seac DX200 Regulator - YOKE is backordered and will ship as soon as it is back in stock.
Pickup available at In Store
Usually ready in 2 hours
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Save with Open Box or Used Purchase
Save with a package
Ready-made packages that include this item
Product Information
The Seac DX200 Regulator is a balanced diaphragm first stage and balanced second stage regulator set, built with a forged brass first stage body and a sand-blasted/sanded chrome finish, that maintains constant intermediate pressure throughout the dive at all depths. It is manufactured in Italy and offered in YOKE and DIN configurations.
Who it is for
The DX200 suits divers who want reliable airflow from a balanced 1st and 2nd stage pairing and flexible hose routing for building out a complete scuba setup. The second stage lets a diver adjust both inhalation sensitivity and the Venturi effect, and the front cover design is intended to resist free-flow in strong currents, which matters for divers who move between varying conditions.
Key details
- Balanced diaphragm first stage in forged brass, minimizing weight and size
- 2 high-pressure ports and 4 low-pressure ports at varying angles for hose routing
- Removable stainless steel valve seat for easier maintenance
- Anti-scratch, anti-corrosion front cover treatment on the second stage
- Adjustment knobs designed to be usable with thick gloves
- Manufactured in Italy
Compatibility and sizing
The DX200 is offered in YOKE and DIN connections; Seac publishes INT 230 BAR and DIN 300 BAR pressure configurations. A DX200 ICE version is also available with a sealed and insulated first stage for cold-water diving, while using the same second stage as the standard DX200.
DiveCatalog.com is an authorized Seac dealer and a dive shop in Irvine, California, open since 2003. Call 888-701-4017 or chat with us if you have questions about fit, port configuration, or DIN versus YOKE compatibility before you order.
- Forged brass first stage: Balanced diaphragm design in forged brass minimizes weight and size.
- Constant intermediate pressure: The balanced first stage maintains constant intermediate pressure throughout the dive at all depths.
- Flexible port layout: 2 high-pressure ports and 4 low-pressure ports at varying angles support flexible hose routing.
- Serviceable valve seat: Removable stainless steel valve seat simplifies maintenance and overhaul.
- Adjustable second stage: Allows regulation of both inhalation sensitivity and the Venturi effect.
- Free-flow resistant cover: OWS front cover design is intended to prevent free-flow in strong currents.
- Durable finish: Anti-scratch, anti-corrosion treatment on the second stage front cover.
- Glove-friendly controls: Adjustment knobs are designed to be usable with thick gloves.
- Cold-water option: A DX200 ICE version is available with a sealed and insulated first stage, retaining the same second stage.
- Configuration options: Available in YOKE and DIN connections.
| First stage type | Balanced diaphragm |
| First stage material | Forged brass, sand-blasted/sanded chrome finish |
| First stage valve seat | Removable stainless steel |
| HP ports | 2 |
| LP ports | 4, at varying angles |
| Second stage material | Technopolymer and elastomer body with metal components, anti-scratch and anti-corrosion front cover |
| Pressure ratings | INT 230 BAR or DIN 300 BAR (DIN 230 bar version available for US market only) |
| Country of manufacture | Italy |
| Regulator type options | YOKE, DIN |
| Cold-water version | DX200 ICE with sealed and insulated first stage, same second stage as standard DX200 |
⚠️ WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, visit www.P65Warnings.ca.gov.
Frequently Asked Questions
How often does a scuba regulator need servicing?
Follow the interval in your regulator's manual, since manufacturers commonly specify an annual inspection or a set number of dives and many warranties depend on it. A regulator is life-support equipment, so service belongs with a factory-trained technician rather than being attempted at home. Have it looked at sooner than scheduled if you notice increased breathing effort, free-flow, bubbles, or water in the second stage.
How do I rinse and care for a regulator after diving?
Make sure the dust cap is dry and firmly seated over the first-stage inlet before the regulator goes anywhere near water, because water inside the first stage is the leading cause of internal corrosion. Rinse in fresh water without pressing the purge button, since purging while depressurized can draw water back into the second stage. Shake out the water and hang it to dry with the hoses in wide, gentle loops rather than tight bends.
Can I fly with a scuba regulator?
Regulators travel well and are usually best carried in hand luggage where they will not be crushed or lost. A regulator holds no gas of its own, so there is nothing inherently problematic about it on an aircraft, though the airline and security screeners always have the final say. Pack it dry with the dust cap in place, in a padded regulator bag or wrapped in soft gear.
Can I use my regulator with nitrox?
Many modern regulators are supplied as suitable for nitrox mixes up to 40 percent oxygen, which is the widely used recreational industry standard, while anything above that requires dedicated oxygen-clean equipment and procedures. Confirm what your specific regulator's manual states, and follow your nitrox training and your fill station's requirements. Never assume a regulator is oxygen-service clean simply because it looks clean or is new.
What is the difference between DIN and yoke regulators?
A yoke (A-clamp) fitting clamps over the tank valve and is the most common connection across much of the recreational world, while a DIN fitting screws into the valve and is standard in much of Europe and in technical diving. DIN captures the o-ring inside the threads, which many divers consider more secure, but yoke is often what rental cylinders provide. Adapters exist in both directions, so check what is used where you dive before deciding.
What is the octopus regulator for?
The octopus is your backup second stage, carried so you can share air with a buddy who is out of gas, or breathe from it yourself if your primary fails or free-flows. It is normally on a longer, brightly colored hose so it is easy to find and hand over under stress. Secure it in the triangle between your chin and the bottom of your rib cage so it is instantly accessible and not dragging through sand or coral.
How should I store a regulator between dive trips?
Store it fully dry, out of sunlight, with the dust cap in place and the hoses in wide loops rather than tightly coiled. Avoid hanging it by the second stages for long periods, which stresses the hose fittings; laying it flat in a padded bag or hanging it by the first stage is kinder. If it has sat unused for a long stretch, have it checked before your next trip rather than assuming it is ready to dive.
What's the difference between the DX200 and the DX200 ICE?
The DX200 ICE is a cold-water version of the same regulator, built with a sealed and insulated first stage while keeping the same second stage as the standard DX200. The standard DX200 does not include this cold-water sealing. Choose the ICE version if you dive in conditions cold enough to risk first-stage freeze-up.
Does the Seac DX200 come in DIN or Yoke?
Yes, the DX200 comes in YOKE and DIN. Seac lists INT 230 BAR and DIN 300 BAR configurations, plus a US-market DIN 230 bar version.
How many ports does the Seac DX200 have for attaching accessories?
The DX200 first stage has 2 high-pressure ports and 4 low-pressure ports positioned at varying angles. This layout gives room to route hoses for a computer, octopus, inflator, and gauge console across the first stage body.
Where is the Seac DX200 regulator made and what is the first stage body material?
The DX200 is manufactured in Italy. Its first stage body is forged brass with a sand-blasted/sanded chrome finish, and it uses a removable stainless steel valve seat to simplify servicing.