Free 1-2 Day Shipping | Get up to 10% cashback | Need It Today? Same-Day Delivery Within 50 Miles

Mares Air Control Regulator

Mares  |  SKU: 416893NR
(11)
Refer & Earn

Sold out
Regular price $220.96
Shipping calculated at checkout.



Pick accessories — 90% off with your $50+ order

and your picks are free.

 

Start  $501 pick $1252 picks
  • DiveCatalog DIN Cap for 1st Stage (Female) for Scuba Diving Tanks - Scuba Essentials

    $19.95$2.00

    1
  • DiveCatalog Hose Clamp for Scuba Diving - Scuba Essentials

    $17.95$1.80

    1
  • DiveCatalog Neoprene Mask Strap Cover

    $17.00$1.70

    1
  • DiveCatalog Silicone Mouthpiece Replacement w/ installation - Scuba Essentials

    $14.95$1.50

    1
  • DiveCatalog Rubber Tank Valve Protector for Scuba Diving Tanks - Scuba Essentials

    $11.95$1.20

    1


Payment & Security

Payment methods

  • Amazon
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Product Information

The Mares Air Control is an octopus regulator that combines a second stage and a jacket inflation control into a single hose, built from Ultralight Technopolymer and weighing 241 grams at the second stage. It is designed for divers who want to carry one hose instead of two separate inflator and octopus hoses, with a pre-oriented mouthpiece and a large purge button for easy, one-handed operation.

Who it is for

This regulator suits divers looking to simplify their rig by merging the octopus second stage and the BCD inflator function into a single hose. The pre-oriented mouthpiece makes it ideal as an octopus, and the ergonomic shape makes it suitable for one-handed operation. The large purge button is sized to work even with thick gloves, which is useful for divers wearing gloves in colder water.

Key details

  • Material: Ultralight Technopolymer
  • Second stage weight: 241 grams
  • Hose type: Superflex hose
  • Gas used: Air

The cover uses the Mesh-Grid system to manage water inlet and outlet flow at the second stage diaphragm, intended to reduce free flow impact during strong currents. Vortex Assisted Design (VAD) routes air through a bypass tube to the mouthpiece, and the Fluid Dynamic Deflector directs that airflow from the bypass tube into the mouthpiece.

Compatibility and sizing

The Air Control is equipped with a Superflex hose, chosen for its light weight and softness to help preserve freedom of movement while diving.

DiveCatalog.com is an authorized Mares dealer and a dive shop in Irvine, California since 2003. Call 888-701-4017 or chat with us if you have questions about fit or compatibility with your current regulator setup.

⚠️ WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, visit www.P65Warnings.ca.gov.

Frequently Asked Questions

How often does a scuba regulator need servicing?

Follow the interval in your regulator's manual, since manufacturers commonly specify an annual inspection or a set number of dives and many warranties depend on it. A regulator is life-support equipment, so service belongs with a factory-trained technician rather than being attempted at home. Have it looked at sooner than scheduled if you notice increased breathing effort, free-flow, bubbles, or water in the second stage.

How do I rinse and care for a regulator after diving?

Make sure the dust cap is dry and firmly seated over the first-stage inlet before the regulator goes anywhere near water, because water inside the first stage is the leading cause of internal corrosion. Rinse in fresh water without pressing the purge button, since purging while depressurized can draw water back into the second stage. Shake out the water and hang it to dry with the hoses in wide, gentle loops rather than tight bends.

Can I fly with a scuba regulator?

Regulators travel well and are usually best carried in hand luggage where they will not be crushed or lost. A regulator holds no gas of its own, so there is nothing inherently problematic about it on an aircraft, though the airline and security screeners always have the final say. Pack it dry with the dust cap in place, in a padded regulator bag or wrapped in soft gear.

Can I use my regulator with nitrox?

Many modern regulators are supplied as suitable for nitrox mixes up to 40 percent oxygen, which is the widely used recreational industry standard, while anything above that requires dedicated oxygen-clean equipment and procedures. Confirm what your specific regulator's manual states, and follow your nitrox training and your fill station's requirements. Never assume a regulator is oxygen-service clean simply because it looks clean or is new.

What is the difference between DIN and yoke regulators?

A yoke (A-clamp) fitting clamps over the tank valve and is the most common connection across much of the recreational world, while a DIN fitting screws into the valve and is standard in much of Europe and in technical diving. DIN captures the o-ring inside the threads, which many divers consider more secure, but yoke is often what rental cylinders provide. Adapters exist in both directions, so check what is used where you dive before deciding.

What is the octopus regulator for?

The octopus is your backup second stage, carried so you can share air with a buddy who is out of gas, or breathe from it yourself if your primary fails or free-flows. It is normally on a longer, brightly colored hose so it is easy to find and hand over under stress. Secure it in the triangle between your chin and the bottom of your rib cage so it is instantly accessible and not dragging through sand or coral.

How should I store a regulator between dive trips?

Store it fully dry, out of sunlight, with the dust cap in place and the hoses in wide loops rather than tightly coiled. Avoid hanging it by the second stages for long periods, which stresses the hose fittings; laying it flat in a padded bag or hanging it by the first stage is kinder. If it has sat unused for a long stretch, have it checked before your next trip rather than assuming it is ready to dive.

What does the Mesh-Grid system on the Mares Air Control do?

The Mesh-Grid system is a patented cover design on the second stage that manages water inlet and outlet flow around the diaphragm. It is intended to reduce the impact of water flow on the diaphragm, which helps limit free flows even when diving in strong currents.

Can the Mares Air Control replace both my octopus and inflator hose?

Yes. The Air Control is built to combine the function of an octopus second stage and a jacket inflation control into a single hose, so you carry one hose instead of separate octopus and low pressure inflator hoses on your regulator setup.

What is Vortex Assisted Design (VAD) on the Mares Air Control?

VAD is a feature where an air bypass tube delivers air to the mouthpiece and creates a swirling vortex with a low pressure area at its center. This is designed to keep the diaphragm down during inhalation for easier breathing, with the Fluid Dynamic Deflector directing that airflow from the bypass tube to the mouthpiece.

Review summary

4.0 11 ratings across the web