Oceanic ZEO FDX-I Regulator with Maxflex Swivel Hose Set
In stock — ships from Irvine, CA
This item is currently on backorder. Order now to reserve yours, and we will ship it as soon as it is back in stock.
Oceanic ZEO FDX-I Regulator with Maxflex Swivel Hose Set - DIN is backordered and will ship as soon as it is back in stock.
Pickup available at In Store
Usually ready in 2 hours
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Save with Open Box or Used Purchase
Save with a package
Ready-made packages that include this item
Save $659.85 (24% off)
Save $44.99 (3% off)
Save $44.99 (3% off)
Product Information
The Oceanic ZEO FDX-i Regulator Set pairs the pneumatically balanced ZEO second stage with the cold-forged, over-balanced diaphragm FDX-i first stage, built for divers who want consistent breathing performance in cold water and available with a Yoke or 300 bar DIN fitting.
Who it is for
This set suits divers who spend time in cold or temperate water and want a regulator that resists the dry-mouth feeling that comes with long, cold dives, as well as travel divers who benefit from the FDX-i's compact, lightweight, in-line first stage body. It also fits nitrox divers, since both stages are standard to 40 percent oxygen, and anyone who wants diver-adjustable airflow control rather than a fixed breathing response.
Key details
- Second stage: ZEO, pneumatically balanced demand valve with a chrome-plated marine brass valve housing
- First stage: FDX-i, cold-forged, over-balanced diaphragm design with environmental sealing
- Work of breathing: 0.86 joules, factory-set inhalation effort of 0.0 to 2.5 inches of water column
- Second stage weight: 7.2 ounces without hose; dimensions 2.3 inches by 3 inches, oval shape
- First stage ports: 4 low pressure and 2 high pressure, angled; first stage weight 21 ounces in Yoke configuration
- Nitrox compatible to 40 percent on both stages
- Patented Dynamic Adjustment, A.V.S. dive/pre-dive switch, in-line ball swivel, and orthodontic mouthpiece with tabs
Compatibility and sizing
The set is offered in two tank-valve configurations: a standard Yoke (A-clamp) fitting and an optional 300 bar DIN fitting. Choose the connection that matches the valves on the tanks you dive most often.
What's in the box
- ZEO second stage
- FDX-i first stage
- Maxflex swivel hose
DiveCatalog.com is an authorized Oceanic dealer and has operated as a dive shop in Irvine, California since 2003, so call or chat with us at 888-701-4017 if you have questions about DIN versus Yoke fit or nitrox compatibility for your setup.
- Pneumatically balanced second stage: The ZEO second stage is a demand valve engineered for a consistent breathing profile at any depth.
- Chrome-plated marine brass valve: A tough, corrosion-resistant all-metal valve improves cold-water performance and the breathing experience.
- Moisture recirculation: The all-metal valve encourages condensation to recirculate with inhaled airflow, helping reduce dry mouth.
- Patented Dynamic Adjustment: Lets the diver control airflow and inhalation effort at the second stage.
- A.V.S. dive/pre-dive switch: Adjustable Venturi Switch helps prevent free-flow at the surface and on deck.
- In-line ball swivel: Reduces jaw fatigue by letting the hose rotate with head movement.
- Orthodontic mouthpiece with tabs: Designed for a comfortable, secure bite.
- FDX-i over-balanced diaphragm first stage: Cold-forged from marine brass for a durable, over-balanced design.
- Environmentally sealed first stage: A secondary diaphragm isolates the main spring cavity from water and contaminants.
- In-line first stage body: Limits the pressure loss typical of 'L' shaped first stages, improving efficiency and reducing weight.
- Nitrox standard to 40 percent: Both the ZEO second stage and FDX-i first stage are nitrox compatible standard to 40%.
- DIN or Yoke configurations: The first stage is available with a standard Yoke or an optional 300 bar DIN fitting.
| Brand | Oceanic |
| Model | ZEO second stage with FDX-i first stage |
| Second Stage Valve Type | Demand, pneumatically balanced |
| Second Stage Adjustments | Patented Dynamic Adjustment; Adjustable Venturi Switch (A.V.S.) for dive/pre-dive |
| Second Stage Mouthpiece | Orthodontic with tabs |
| Second Stage Nitrox Compatibility | Standard to 40% |
| Second Stage Weight (without hose) | 7.2 ounces |
| Second Stage Dimensions | 2.3 inch x 3 inch, oval shape |
| Second Stage Work of Breathing | 0.86 joules |
| Second Stage Factory Set Inhalation Effort | 0.0 to 2.5 IWC |
| Second Stage Integrated Purge Button | Yes |
| First Stage Valve Type | Over-balanced diaphragm |
| First Stage Primary Material | Forged marine brass |
| First Stage Ports | 4 low pressure and 2 high pressure, angled |
| First Stage Nitrox Compatibility | Standard to 40% |
| First Stage DIN Fitting | 300 bar DIN fitting (optional) |
| First Stage Environmental Protection | Sealed valve design |
| First Stage Weight (Yoke) | 21 ounces |
| Hose | Maxflex swivel hose included |
- ZEO second stage
- FDX-i first stage
- Maxflex swivel hose
⚠️ WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, visit www.P65Warnings.ca.gov.
Frequently Asked Questions
How often does a scuba regulator need servicing?
Follow the interval in your regulator's manual, since manufacturers commonly specify an annual inspection or a set number of dives and many warranties depend on it. A regulator is life-support equipment, so service belongs with a factory-trained technician rather than being attempted at home. Have it looked at sooner than scheduled if you notice increased breathing effort, free-flow, bubbles, or water in the second stage.
How do I rinse and care for a regulator after diving?
Make sure the dust cap is dry and firmly seated over the first-stage inlet before the regulator goes anywhere near water, because water inside the first stage is the leading cause of internal corrosion. Rinse in fresh water without pressing the purge button, since purging while depressurized can draw water back into the second stage. Shake out the water and hang it to dry with the hoses in wide, gentle loops rather than tight bends.
Can I fly with a scuba regulator?
Regulators travel well and are usually best carried in hand luggage where they will not be crushed or lost. A regulator holds no gas of its own, so there is nothing inherently problematic about it on an aircraft, though the airline and security screeners always have the final say. Pack it dry with the dust cap in place, in a padded regulator bag or wrapped in soft gear.
Can I use my regulator with nitrox?
Many modern regulators are supplied as suitable for nitrox mixes up to 40 percent oxygen, which is the widely used recreational industry standard, while anything above that requires dedicated oxygen-clean equipment and procedures. Confirm what your specific regulator's manual states, and follow your nitrox training and your fill station's requirements. Never assume a regulator is oxygen-service clean simply because it looks clean or is new.
What is the difference between DIN and yoke regulators?
A yoke (A-clamp) fitting clamps over the tank valve and is the most common connection across much of the recreational world, while a DIN fitting screws into the valve and is standard in much of Europe and in technical diving. DIN captures the o-ring inside the threads, which many divers consider more secure, but yoke is often what rental cylinders provide. Adapters exist in both directions, so check what is used where you dive before deciding.
What is the octopus regulator for?
The octopus is your backup second stage, carried so you can share air with a buddy who is out of gas, or breathe from it yourself if your primary fails or free-flows. It is normally on a longer, brightly colored hose so it is easy to find and hand over under stress. Secure it in the triangle between your chin and the bottom of your rib cage so it is instantly accessible and not dragging through sand or coral.
How should I store a regulator between dive trips?
Store it fully dry, out of sunlight, with the dust cap in place and the hoses in wide loops rather than tightly coiled. Avoid hanging it by the second stages for long periods, which stresses the hose fittings; laying it flat in a padded bag or hanging it by the first stage is kinder. If it has sat unused for a long stretch, have it checked before your next trip rather than assuming it is ready to dive.
What is included in the Oceanic ZEO FDX-i regulator set?
The set includes the ZEO second stage, the FDX-i first stage, and a Maxflex swivel hose connecting them. The first stage is available with a standard Yoke fitting or an optional 300 bar DIN fitting. Octopus regulators, pressure gauges, and other accessories are sold separately.
How much does the Oceanic FDX-i first stage weigh?
The FDX-i first stage weighs 21 ounces in the Yoke configuration. Its cold-forged, in-line diaphragm body limits the pressure loss typical of 'L' type first stages, improving efficiency and reducing weight.
Is the Oceanic ZEO second stage balanced or unbalanced?
The ZEO is a pneumatically balanced demand valve, which helps keep breathing effort consistent as tank pressure drops and at depth. It is rated at 0.86 joules of work of breathing, with a factory-set inhalation effort between 0.0 and 2.5 inches of water column, and pairs with the over-balanced diaphragm FDX-i first stage.
What makes the ZEO regulator suited to cold-water diving?
The ZEO uses a corrosion-resistant chrome-plated marine brass valve, and its all-metal housing lets exhaled condensation recirculate with incoming airflow, reducing dry mouth. The FDX-i first stage is environmentally sealed, with a secondary diaphragm isolating the main spring cavity to help resist the effects of cold water.













