Holis 150LX DC7 Dive Regulator Set
In stock — ships from Irvine, CA
This item is currently on backorder. Order now to reserve yours, and we will ship it as soon as it is back in stock.
Holis 150LX DC7 Dive Regulator Set - DIN is backordered and will ship as soon as it is back in stock.
Pickup available at In Store
Usually ready in 2 hours
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Save with Open Box or Used Purchase
Save with a package
Ready-made packages that include this item
Save $44.99 (2% off)
Save $56.99 (4% off)
Product Information
The Hollis 150LX DC7 Dive Regulator Set is a complete first and second stage package that pairs the pneumatically balanced 150LX second stage with the over-balanced, environmentally sealed DC7 diaphragm first stage, available in DIN or Yoke and rated for Nitrox up to 40% oxygen. It mirrors the design and breathing performance of the 200LX but without PVD plating and without the diver inhalation adjustment, making it a straightforward choice as either a primary regulator or a deco regulator.
Who it is for
This set suits recreational and technical divers who want balanced, easy breathing in a travel-friendly package, including divers diving cold water and divers running a deco or stage bottle alongside a primary rig. The DC7 first stage uses fixed hose routing and works in both backmount and sidemount configurations, and the reversible 150LX demand valve can be converted between right-handed and left-handed hose routing, so the set adapts to how you build your kit.
Key details
- DC7 first stage: over-balanced diaphragm, environmentally sealed against corrosion, contaminants and icing, 300 bar working pressure.
- Port layout: 2 high pressure ports and 4 low pressure ports with fixed hose routing.
- 150LX second stage: pneumatically balanced chrome-plated brass valve, 316 stainless steel front metal ring, packing nut and end cap.
- Adjustable Dive/Pre-Dive switch with a large Venturi lever and soft rubber grip.
- Ergonomic exhaust channels bubbles away from your field of view and reduce exhaust effort.
- MiFlex braided hose and an improved orthodontic mouthpiece with dual color tabs.
- Designed to meet CE cold water performance requirements; supplied O2 cleaned in a sealed bag.
- Lifetime Warranty, Free Parts for Life and a 2-year service interval with inspection.
Compatibility and sizing
Choose DIN (300 bar) or Yoke to match the tank valves you dive. Gas compatibility is Nitrox up to 40% oxygen. The first stage is suitable for backmount and sidemount setups.
DiveCatalog.com is an authorized Hollis dealer and a real dive shop in Irvine, California since 2003. Call 888-701-4017 or start a chat if you want help choosing DIN or Yoke, or confirming how this set fits your current hose and port layout.
- Pneumatically balanced second stage chrome-plated brass valve for smooth, easy breathing across a range of conditions.
- Over-balanced DC7 first stage delivers progressively greater intermediate pressure as depth and gas density increase.
- Environmentally sealed first stage protects against internal corrosion, contaminants and icing.
- 300 bar working pressure with 2 high pressure ports and 4 low pressure ports and fixed hose routing.
- DIN or Yoke connection options so the set matches your tank valves.
- Reversible demand valve converts between right-handed and left-handed hose configuration.
- Adjustable Dive/Pre-Dive switch with a large Venturi lever and soft rubber grip for easy operation.
- Ergonomic exhaust channels direct bubbles away from the field of view and reduce exhaust effort.
- 316 stainless steel hardware on the second stage front metal ring, packing nut and end cap.
- MiFlex braided hose plus an improved orthodontic mouthpiece with dual color tabs for long-dive comfort.
- Cold water ready and designed to meet CE standard requirements for coldwater performance.
- Nitrox to 40% and O2 cleaned in a sealed bag; Lifetime Warranty, Free Parts for Life, 2-year service interval with inspection.
| Brand | Hollis |
| Model | 150LX second stage with DC7 first stage |
| Connection | DIN or Yoke options available |
| First Stage Working Pressure | 300 bar |
| First Stage Type | DC7 over-balanced diaphragm, environmentally sealed |
| HP Ports | 2 |
| LP Ports | 4 |
| Hose Routing | Fixed |
| Second Stage | 150LX pneumatically balanced |
| Second Stage Valve Body | Chrome-plated brass |
| Front Ring, Packing Nut, End Cap | 316 stainless steel |
| Demand Valve | Reversible for left or right hose routing |
| Venturi | Adjustable Dive/Pre-Dive lever with rubber grip |
| Mouthpiece | Orthodontic with dual color tabs |
| Hose | MiFlex braided |
| Cold Water | Suitable for coldwater diving |
| Certification | Designed to meet CE coldwater performance standard |
| Gas Compatibility | Nitrox up to 40% oxygen |
| Configurations | Backmount and sidemount |
| Warranty | Lifetime Warranty with Free Parts for Life |
| Service Interval | 2 years with inspection |
| SKU (DIN) | 240.1503.07.M |
| SKU (Yoke) | 240.1504.07.M-PB1 |
⚠️ WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, visit www.P65Warnings.ca.gov.
Frequently Asked Questions
How often does a scuba regulator need servicing?
Follow the interval in your regulator's manual, since manufacturers commonly specify an annual inspection or a set number of dives and many warranties depend on it. A regulator is life-support equipment, so service belongs with a factory-trained technician rather than being attempted at home. Have it looked at sooner than scheduled if you notice increased breathing effort, free-flow, bubbles, or water in the second stage.
How do I rinse and care for a regulator after diving?
Make sure the dust cap is dry and firmly seated over the first-stage inlet before the regulator goes anywhere near water, because water inside the first stage is the leading cause of internal corrosion. Rinse in fresh water without pressing the purge button, since purging while depressurized can draw water back into the second stage. Shake out the water and hang it to dry with the hoses in wide, gentle loops rather than tight bends.
Can I fly with a scuba regulator?
Regulators travel well and are usually best carried in hand luggage where they will not be crushed or lost. A regulator holds no gas of its own, so there is nothing inherently problematic about it on an aircraft, though the airline and security screeners always have the final say. Pack it dry with the dust cap in place, in a padded regulator bag or wrapped in soft gear.
Can I use my regulator with nitrox?
Many modern regulators are supplied as suitable for nitrox mixes up to 40 percent oxygen, which is the widely used recreational industry standard, while anything above that requires dedicated oxygen-clean equipment and procedures. Confirm what your specific regulator's manual states, and follow your nitrox training and your fill station's requirements. Never assume a regulator is oxygen-service clean simply because it looks clean or is new.
What is the difference between DIN and yoke regulators?
A yoke (A-clamp) fitting clamps over the tank valve and is the most common connection across much of the recreational world, while a DIN fitting screws into the valve and is standard in much of Europe and in technical diving. DIN captures the o-ring inside the threads, which many divers consider more secure, but yoke is often what rental cylinders provide. Adapters exist in both directions, so check what is used where you dive before deciding.
What is the octopus regulator for?
The octopus is your backup second stage, carried so you can share air with a buddy who is out of gas, or breathe from it yourself if your primary fails or free-flows. It is normally on a longer, brightly colored hose so it is easy to find and hand over under stress. Secure it in the triangle between your chin and the bottom of your rib cage so it is instantly accessible and not dragging through sand or coral.
How should I store a regulator between dive trips?
Store it fully dry, out of sunlight, with the dust cap in place and the hoses in wide loops rather than tightly coiled. Avoid hanging it by the second stages for long periods, which stresses the hose fittings; laying it flat in a padded bag or hanging it by the first stage is kinder. If it has sat unused for a long stretch, have it checked before your next trip rather than assuming it is ready to dive.
What is the difference between the Hollis 200LX and the 150LX?
Both second stages are pneumatically balanced and pair with the same DC7 first stage, but the 200LX is the higher-tier model. The 200LX adds a PVD-coated brass body plus an adjustable inhalation knob and venturi lever; the 150LX is essentially the same design without the PVD coating and without the adjustable inhalation knob.
What is the Hollis DC7 first stage on the 150LX and 200LX?
The DC7 is an over-balanced diaphragm first stage that is environmentally sealed and CE rated for cold water. It provides 2 high-pressure and 4 low-pressure ports and is rated for Nitrox up to 40%. It is the shared first stage for both the 150LX and 200LX sets.
What warranty and service does the Hollis 150LX / 200LX carry?
Hollis backs these regulators with a Lifetime warranty plus Free Parts for Life, and the recommended service interval is every 2 years with inspection. Hollis warranty coverage requires purchase from an authorized dealer, and purchases from us qualify.
Can the Hollis 150LX DC7 set be used for sidemount diving?
Yes. The DC7 first stage is suitable for both backmount and sidemount configurations. It uses fixed hose routing with 2 high pressure and 4 low pressure ports, and the 150LX second stage has a reversible demand valve that converts between right-handed and left-handed hose configuration, so you can set the hose to exit on the side your sidemount or stage bottle layout requires.
What does the DC7 over-balanced design actually do?
An over-balanced first stage increases intermediate pressure progressively as depth and gas density increase, so the second stage keeps delivering gas easily at depth rather than getting harder to breathe. The DC7 is also an environmentally sealed diaphragm design, which protects the internals from corrosion, contaminants and icing, and it is designed to meet CE standard requirements for coldwater performance.
What materials are used in the 150LX second stage?
The 150LX uses a chrome-plated brass pneumatically balanced valve body, and the front metal ring, packing nut and end cap are 316 stainless steel. It is fitted with an improved orthodontic mouthpiece with dual color tabs and a MiFlex braided hose. The 150LX shares the 200LX design but without PVD plating and without the diver inhalation adjustment knob.
Is the 150LX DC7 set supplied ready for nitrox?
Yes. Both the 150LX second stage and the DC7 first stage are rated for oxygen percentages up to 40%, and the set is supplied O2 cleaned in a sealed bag. Mixes above 40% require dedicated oxygen-clean equipment and procedures, so follow your training agency's standards and the Hollis manual for anything beyond 40%.














