Free 1-2 Day Shipping | Get up to 10% cashback | Need It Today? Same-Day Delivery Within 50 Miles

HOLLIS 150LX + H02 DIN (O2 REGULATOR)

Hollis  |  SKU: 240.1502.19.M
Refer & Earn

Regular price $579.95
Shipping calculated at checkout.

In stock — ships from Irvine, CA


Type

Pickup available at In Store

Usually ready in 2 hours


Pick an accessory — 90% off with your $250+ order

and your accessory is free.

 

$2502 items $5003 items $1,0005 items $1,5006 items $2,0008 items $3,00010 items $4,00012 items $5,00015 items
  • DiveCatalog.com Quick Dry Multi Accessory Dive Gear Hanger for Boots, Gloves, Hood

    $22.95$2.30

  • DiveCatalog DIN Cap for 1st Stage (Female) for Scuba Diving Tanks - Scuba Essentials

    $19.95$2.00

  • DiveCatalog Comfo-Bite Silicone Mouthpiece for Scuba Diving Regulators Black

    $19.95$2.00

  • DiveCatalog Scuba Essentials - Wetsuit Hanger for Scuba Diving, Snorkeling, and Surfing

    $19.95$2.00

  • DiveCatalog Essentials - BCD and Regulator Hanger for Scuba Diving

    $19.95$2.00


Payment & Security

Payment methods

  • Amazon
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Save with Open Box or Used Purchase

Product Information

The Hollis 150LX + HO2 DIN is a 100% oxygen compatible first and second stage regulator set for divers breathing oxygen-rich mixes, pairing the 150LX second stage with the HO2 first stage on a DIN hand-wheel rated to 300 BAR/4500 PSI. The 150LX follows the design and overall performance of the 200LX but without PVD plating and diver inhalation adjustment, and the oxygen green hand-wheel makes the set easy to identify on a bench full of gear.

Who it is for

This set suits divers who need a dedicated regulator for oxygen-rich diving applications without stepping up to the 200LX. The DIN configuration screws directly into DIN cylinder valves. The first stage has 4 threaded 3/8" low-pressure ports and 1 threaded 7/16" high-pressure port.

Key details

  • HO2 first stage: non-balanced flow-by piston on the Hollis HP5 platform, certified for up to 100% oxygen service.
  • Fail-safe flow-by piston design: the piston moves downstream automatically if the high-pressure seat malfunctions, maintaining gas flow to the second stage.
  • Cleaned and assembled in a clean room with specially designed materials and halocarbon-based lubricants.
  • Marine-grade chrome-plated brass first stage weighing 8.3 oz (235.3 g).
  • Ports: 4 threaded 3/8" LP, 1 threaded 7/16" HP.
  • Second stage front metal ring, packing nut and end cap in 316 stainless steel.
  • MiFlex hose and orthodontic mouthpiece with dual-color tabs as standard.
  • Lifetime warranty with a 2-year service interval and Free Parts for Life.

What's in the box

  • 150LX second stage
  • HO2 first stage
  • MiFlex hose
  • Orthodontic mouthpiece with dual-color tabs

DiveCatalog.com is an authorized Hollis dealer and a real dive shop in Irvine, California since 2003. Call or chat with us at 888-701-4017 if you want help confirming DIN valve fit, port routing or oxygen-service handling for your setup.

⚠️ WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, visit www.P65Warnings.ca.gov.

Frequently Asked Questions

How often does a scuba regulator need servicing?

Follow the interval in your regulator's manual, since manufacturers commonly specify an annual inspection or a set number of dives and many warranties depend on it. A regulator is life-support equipment, so service belongs with a factory-trained technician rather than being attempted at home. Have it looked at sooner than scheduled if you notice increased breathing effort, free-flow, bubbles, or water in the second stage.

How do I rinse and care for a regulator after diving?

Make sure the dust cap is dry and firmly seated over the first-stage inlet before the regulator goes anywhere near water, because water inside the first stage is the leading cause of internal corrosion. Rinse in fresh water without pressing the purge button, since purging while depressurized can draw water back into the second stage. Shake out the water and hang it to dry with the hoses in wide, gentle loops rather than tight bends.

Can I fly with a scuba regulator?

Regulators travel well and are usually best carried in hand luggage where they will not be crushed or lost. A regulator holds no gas of its own, so there is nothing inherently problematic about it on an aircraft, though the airline and security screeners always have the final say. Pack it dry with the dust cap in place, in a padded regulator bag or wrapped in soft gear.

Can I use my regulator with nitrox?

Many modern regulators are supplied as suitable for nitrox mixes up to 40 percent oxygen, which is the widely used recreational industry standard, while anything above that requires dedicated oxygen-clean equipment and procedures. Confirm what your specific regulator's manual states, and follow your nitrox training and your fill station's requirements. Never assume a regulator is oxygen-service clean simply because it looks clean or is new.

What is the difference between DIN and yoke regulators?

A yoke (A-clamp) fitting clamps over the tank valve and is the most common connection across much of the recreational world, while a DIN fitting screws into the valve and is standard in much of Europe and in technical diving. DIN captures the o-ring inside the threads, which many divers consider more secure, but yoke is often what rental cylinders provide. Adapters exist in both directions, so check what is used where you dive before deciding.

What is the octopus regulator for?

The octopus is your backup second stage, carried so you can share air with a buddy who is out of gas, or breathe from it yourself if your primary fails or free-flows. It is normally on a longer, brightly colored hose so it is easy to find and hand over under stress. Secure it in the triangle between your chin and the bottom of your rib cage so it is instantly accessible and not dragging through sand or coral.

How should I store a regulator between dive trips?

Store it fully dry, out of sunlight, with the dust cap in place and the hoses in wide loops rather than tightly coiled. Avoid hanging it by the second stages for long periods, which stresses the hose fittings; laying it flat in a padded bag or hanging it by the first stage is kinder. If it has sat unused for a long stretch, have it checked before your next trip rather than assuming it is ready to dive.

Can the Hollis 150LX HO2 be used with 100% oxygen?

Yes. The 150LX HO2 is a 100% oxygen compatible regulator set, and the HO2 first stage is certified for up to 100% oxygen service. The HO2 first stage is cleaned and assembled in a clean room using specially designed materials and halocarbon-based lubricants, and the DIN hand-wheel is color-coded oxygen green for identification. Always follow your training agency's procedures for handling oxygen-service equipment.

Is this set DIN or yoke, and what pressure is the DIN fitting rated to?

This SKU, 240.1502.19.M, is the DIN configuration, with a DIN hand-wheel rated to 300 BAR/4500 PSI that screws directly into a DIN cylinder valve. Hollis publishes the 150LX HO2 in both YOKE and DIN configurations. Contact us if you need help confirming which fitting your cylinder valves use.

What does the fail-safe flow-by piston first stage do?

The HO2 uses a non-balanced flow-by piston design that Hollis describes as fail-safe. If the high-pressure seat malfunctions, the piston moves downstream automatically so gas continues flowing to the second stage rather than shutting off. The first stage body is marine-grade chrome-plated brass and weighs 8.3 oz (235.3 g), with 4 threaded 3/8 inch LP ports and 1 threaded 7/16 inch HP port.

What warranty and service interval does Hollis list for this regulator?

Hollis lists a lifetime warranty on the 150LX HO2, a 2-year service interval and Free Parts for Life.