Hollis 500SE + DC7 DIN
In stock — ships from Irvine, CA
This item is currently on backorder. Order now to reserve yours, and we will ship it as soon as it is back in stock.
Hollis 500SE + DC7 DIN - DIN is backordered and will ship as soon as it is back in stock.
Pickup available at In Store
Usually ready in 2 hours
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Save with a package
Ready-made packages that include this item
Save $112.49 (10% off)
Product Information
The Hollis 500SE + DC7 is a complete scuba regulator set that pairs the over-balanced DC7 first stage with the servo-controlled 500SE second stage, built for divers who run backmount or sidemount configurations. The DC7 is environmentally sealed, nitrox compatible to 40 percent, and carries 2 high pressure and 4 low pressure ports, while the 500SE uses a side-exhaust body with a 30 in. maxflex hose and can be mounted for left or right side routing.
Who it is for
This set suits divers moving into sidemount or technical-style setups, as well as backmount divers who want stable breathing performance in cold water. The DC7's over-balanced design delivers progressively greater intermediate pressure as depth and gas density increase, and the 500SE's servo-controlled valve provides airflow control suitable for air and trimix dives. The side-exhaust layout and boltsnap tie point make the second stage practical to stow and deploy in sidemount, where regulators need to sit cleanly on either side.
Key details
- DC7 first stage: over-balanced diaphragm, environmentally sealed against corrosion, contaminants and icing, CE standard coldwater performance.
- Ports: 2 high pressure and 4 low pressure, with fixed hose routing for backmount and sidemount.
- Gas: nitrox compatible to 40 percent.
- 500SE second stage: pneumatically balanced servo valve system, patented orthodontic mouthpiece, 30 in. maxflex hose, tool-free disassembly, left or right positioning, boltsnap tie point, side exhaust.
Compatibility and sizing
Choose DIN for a 300 bar threaded valve connection or YOKE for a standard A-clamp valve. Fixed hose routing on the DC7 is designed to work in both backmount and sidemount rigs, and the 500SE's left or right orientation lets you build a matched pair of sidemount regulators.
DiveCatalog.com is an authorized Hollis dealer and a real dive shop in Irvine, California since 2003. Call 888-701-4017 or start a chat if you want help choosing DIN or YOKE, or confirming how this set fits your backmount or sidemount setup.
- Over-balanced DC7 first stage provides progressively greater intermediate pressure as depth and gas density increase.
- Environmental sealing helps prevent internal corrosion, contaminants and icing.
- CE standard coldwater performance on the DC7 first stage.
- 2 HP and 4 LP ports with fixed hose routing suited to backmount and sidemount configurations.
- Nitrox compatible to 40 percent oxygen content.
- DIN or YOKE styles available, with DIN rated for 300 bar valve connections.
- Servo-controlled 500SE second stage with a pneumatically balanced servo valve system for consistent airflow.
- Side-exhaust second stage body that supports left or right positioning.
- Patented orthodontic mouthpiece for comfort and reduced jaw fatigue.
- 30 in. maxflex hose supplied with the 500SE second stage.
- Tool-free disassembly of the second stage, which can be serviced underwater if necessary.
- Boltsnap tie point on the 500SE for stowing the regulator in sidemount and technical rigs.
| Brand | Hollis |
| Model | 500SE second stage with DC7 first stage |
| Product type | Regulator set, 1st and 2nd stage |
| First stage | DC7 over-balanced diaphragm |
| Styles | 2 (DIN, YOKE) |
| DIN connection | DIN / 300 bar |
| HP ports | 2 |
| LP ports | 4, fixed hose routing |
| Environmental sealing | Sealed against corrosion, contaminants and icing |
| Cold water | CE standard coldwater performance |
| Gas compatibility | Nitrox to 40 percent |
| Second stage valve | Pneumatically balanced servo valve system |
| Exhaust | Side exhaust |
| Orientation | Left or right positioning |
| Mouthpiece | Patented orthodontic mouthpiece |
| Hose | 30 in. maxflex |
| Service access | Tool-free disassembly |
| Attachment | Boltsnap tie point |
| Configurations | Backmount and sidemount |
| Gas use | Air and trimix |
| SKU (DIN) | 240.3501.07.M |
| SKU (YOKE) | 240.3500.07.M |
⚠️ WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, visit www.P65Warnings.ca.gov.
Frequently Asked Questions
How often does a scuba regulator need servicing?
Follow the interval in your regulator's manual, since manufacturers commonly specify an annual inspection or a set number of dives and many warranties depend on it. A regulator is life-support equipment, so service belongs with a factory-trained technician rather than being attempted at home. Have it looked at sooner than scheduled if you notice increased breathing effort, free-flow, bubbles, or water in the second stage.
How do I rinse and care for a regulator after diving?
Make sure the dust cap is dry and firmly seated over the first-stage inlet before the regulator goes anywhere near water, because water inside the first stage is the leading cause of internal corrosion. Rinse in fresh water without pressing the purge button, since purging while depressurized can draw water back into the second stage. Shake out the water and hang it to dry with the hoses in wide, gentle loops rather than tight bends.
Can I fly with a scuba regulator?
Regulators travel well and are usually best carried in hand luggage where they will not be crushed or lost. A regulator holds no gas of its own, so there is nothing inherently problematic about it on an aircraft, though the airline and security screeners always have the final say. Pack it dry with the dust cap in place, in a padded regulator bag or wrapped in soft gear.
Can I use my regulator with nitrox?
Many modern regulators are supplied as suitable for nitrox mixes up to 40 percent oxygen, which is the widely used recreational industry standard, while anything above that requires dedicated oxygen-clean equipment and procedures. Confirm what your specific regulator's manual states, and follow your nitrox training and your fill station's requirements. Never assume a regulator is oxygen-service clean simply because it looks clean or is new.
What is the difference between DIN and yoke regulators?
A yoke (A-clamp) fitting clamps over the tank valve and is the most common connection across much of the recreational world, while a DIN fitting screws into the valve and is standard in much of Europe and in technical diving. DIN captures the o-ring inside the threads, which many divers consider more secure, but yoke is often what rental cylinders provide. Adapters exist in both directions, so check what is used where you dive before deciding.
What is the octopus regulator for?
The octopus is your backup second stage, carried so you can share air with a buddy who is out of gas, or breathe from it yourself if your primary fails or free-flows. It is normally on a longer, brightly colored hose so it is easy to find and hand over under stress. Secure it in the triangle between your chin and the bottom of your rib cage so it is instantly accessible and not dragging through sand or coral.
How should I store a regulator between dive trips?
Store it fully dry, out of sunlight, with the dust cap in place and the hoses in wide loops rather than tightly coiled. Avoid hanging it by the second stages for long periods, which stresses the hose fittings; laying it flat in a padded bag or hanging it by the first stage is kinder. If it has sat unused for a long stretch, have it checked before your next trip rather than assuming it is ready to dive.
Is the Hollis 500SE + DC7 available in yoke as well as DIN?
Yes. This regulator set is offered in two styles, DIN and YOKE. The DIN version uses a 300 bar threaded connection that screws into the tank valve, while the YOKE version clamps over a standard A-clamp valve. Pick the style that matches the cylinders you dive most often, and call us if you dive in regions that use both.
Does the 500SE + DC7 work for sidemount diving?
Yes. The DC7 uses fixed hose routing suitable for backmount and sidemount, and the 500SE has a side-exhaust body with left or right positioning and a boltsnap tie point.
How cold can I dive the DC7 first stage?
The DC7 first stage is environmentally sealed to help prevent internal corrosion, contaminants and icing, and it is built to meet CE standard coldwater performance. Always follow your training and the owner's manual for cold water procedures.
What hose comes on the 500SE second stage?
The 500SE second stage is supplied with a 30 in. maxflex hose. That length suits a primary second stage in many backmount and sidemount setups. If you need a longer hose for air sharing, or a different routing for your rig, contact us at 888-701-4017 and we can talk through options before you order.
Review summary
Reviewers agree this breathes easily and smoothly at any depth or diver position, and that the side exhaust sends bubbles away from your face instead of across your view. Several divers moved to it from long-used Poseidon, Apeks or Scubapro sets. Good to know: it takes a few dives to get used to, and a couple of divers found it heavier than their older regs. It suits photographers, videographers and sidemount or stage divers who want an Omega style side exhaust.
What reviewers like




















