Halcyon Singles Reg Package #2 H-75P ( Halo, Aura) (65.002.004A)
Halcyon Singles Reg Package #2 H-75P ( Halo, Aura) (65.002.004A) is backordered and will ship as soon as it is back in stock.
Pickup currently unavailable at In Store
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Save with a package
Ready-made packages that include this item
Product Information
The Halcyon Singles Reg Package #2 H-75P (Halo, Aura), part number 65.002.004A, is a complete single-cylinder regulator set built around one H-75P balanced, freeze-resistant piston first stage paired with a Halo second stage and an Aura second stage. It ships with a Master SPG, a single-cylinder hose kit, a backup necklace cord and stainless steel bolt snaps, so the whole breathing system arrives configured as one package.
Who it is for
This package suits divers running a single cylinder, from recreational diving through technical training and exploration, who want a primary and a backup second stage selected to work together rather than assembled piecemeal. The H-75P first stage delivers consistent airflow in cold water, and the Aura is compact and lightweight, suitable as either a primary or a backup. Halcyon regulator packages are modular, so the setup can be adapted as diving needs evolve.
Key details
- H-75P first stage: balanced freeze-resistant piston, rotating swivel turret, two HP ports and five high-flow LP ports.
- 300-bar DIN connection with optional yoke compatibility.
- Aura second stage: air-balanced downstream valve with adjustable breathing resistance and a chrome-plated brass valve.
- Nitrox compatible up to 40% oxygen for both the H-75P and the Aura.
- Hose kit: 84" and 22" LP hoses plus a 26" HP hose.
Compatibility and sizing
The 84" LP primary hose can be substituted with a 60" LP hose if you prefer a shorter long hose. The rotating turret on the H-75P allows flexible hose routing to reduce jaw fatigue and accommodates a range of diving configurations. Stainless steel bolt snaps are supplied in 3/8" and 1" sizes.
What's in the box
- 1x H-75P first stage regulator
- 1x Halo second stage regulator
- 1x Aura second stage regulator
- Master SPG
- Single hose kit: LP hoses 84" and 22", HP hose 26"
- Backup necklace cord
- Stainless steel bolt snaps, 3/8" and 1"
DiveCatalog.com is an authorized Halcyon dealer and a dive shop in Irvine, California since 2003. Call or chat with us at 888-701-4017 if you want help choosing hose lengths or confirming DIN versus yoke for your cylinders.
- Complete single-cylinder package Part number 65.002.004A pairs one H-75P first stage with one Halo and one Aura second stage.
- Balanced piston first stage The H-75P uses a balanced, freeze-resistant piston design for consistent airflow in cold water.
- 300-bar DIN connection The H-75P connects via 300-bar DIN with optional yoke compatibility.
- Seven ports Two HP ports and five high-flow LP ports on the H-75P first stage.
- Rotating swivel turret Allows flexible hose routing for comfort, reduced jaw fatigue and multiple diving configurations.
- Air-balanced Aura second stage Balanced downstream valve with adjustable resistance for consistent airflow at any depth.
- Compact backup The Aura is lightweight with a rugged housing and chrome-plated brass valve, suitable as a primary or a backup second stage.
- Nitrox ready to 40% Both the H-75P first stage and the Aura second stage are compatible with mixes up to 40% oxygen.
- Single hose kit included LP hoses in 84" and 22" plus a 26" HP hose, with the 84" hose substitutable for a 60" LP hose.
- Master SPG included Submersible pressure gauge supplied with the package.
- Rigging hardware included Stainless steel bolt snaps in 3/8" and 1" sizes plus a backup necklace cord.
- Modular by design Components are selected to work together for balance, streamlining and predictable operation, and can be adapted as your diving evolves.
| Part Number | 65.002.004A |
| Package Configuration | Single cylinder: H-75P first stage, Halo second stage, Aura second stage |
| First Stage Design | Balanced, freeze-resistant piston |
| First Stage Connection | 300-bar DIN with optional yoke compatibility |
| HP Ports | Two |
| LP Ports | Five high-flow |
| Turret | Rotating swivel turret for flexible hose routing |
| Second Stage Design (Aura) | Air-balanced downstream valve with adjustable resistance |
| Second Stage Materials (Aura) | Chrome-plated brass valve, lightweight rugged housing |
| Gas Compatibility | Nitrox up to 40% oxygen |
| LP Hose Lengths | 84" and 22" (84" may be substituted with 60") |
| HP Hose Length | 26" |
| SPG | Master SPG |
| Bolt Snaps | Stainless steel, 3/8" and 1" |
| Necklace | Backup necklace cord included |
| Intended Use | Recreational diving through technical exploration, training and stage support |
| Serviceability | Serviceable components compatible with Halcyon spare parts and service kits |
| Related Packages | Package #1 H-75P (Halo, Halo) 65.002.004; Package #3 H-50D (Halo, Aura) 65.002.005 |
- 1x H-75P first stage regulator
- 1x Halo second stage regulator
- 1x Aura second stage regulator
- Master SPG
- Single hose kit: LP hoses 84" and 22", HP hose 26"
- Backup necklace cord
- Stainless steel bolt snaps (3/8" and 1")
⚠️ WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, visit www.P65Warnings.ca.gov.
Frequently Asked Questions
How often does a scuba regulator need servicing?
Follow the interval in your regulator's manual, since manufacturers commonly specify an annual inspection or a set number of dives and many warranties depend on it. A regulator is life-support equipment, so service belongs with a factory-trained technician rather than being attempted at home. Have it looked at sooner than scheduled if you notice increased breathing effort, free-flow, bubbles, or water in the second stage.
How do I rinse and care for a regulator after diving?
Make sure the dust cap is dry and firmly seated over the first-stage inlet before the regulator goes anywhere near water, because water inside the first stage is the leading cause of internal corrosion. Rinse in fresh water without pressing the purge button, since purging while depressurized can draw water back into the second stage. Shake out the water and hang it to dry with the hoses in wide, gentle loops rather than tight bends.
Can I fly with a scuba regulator?
Regulators travel well and are usually best carried in hand luggage where they will not be crushed or lost. A regulator holds no gas of its own, so there is nothing inherently problematic about it on an aircraft, though the airline and security screeners always have the final say. Pack it dry with the dust cap in place, in a padded regulator bag or wrapped in soft gear.
Can I use my regulator with nitrox?
Many modern regulators are supplied as suitable for nitrox mixes up to 40 percent oxygen, which is the widely used recreational industry standard, while anything above that requires dedicated oxygen-clean equipment and procedures. Confirm what your specific regulator's manual states, and follow your nitrox training and your fill station's requirements. Never assume a regulator is oxygen-service clean simply because it looks clean or is new.
What is the difference between DIN and yoke regulators?
A yoke (A-clamp) fitting clamps over the tank valve and is the most common connection across much of the recreational world, while a DIN fitting screws into the valve and is standard in much of Europe and in technical diving. DIN captures the o-ring inside the threads, which many divers consider more secure, but yoke is often what rental cylinders provide. Adapters exist in both directions, so check what is used where you dive before deciding.
What is the octopus regulator for?
The octopus is your backup second stage, carried so you can share air with a buddy who is out of gas, or breathe from it yourself if your primary fails or free-flows. It is normally on a longer, brightly colored hose so it is easy to find and hand over under stress. Secure it in the triangle between your chin and the bottom of your rib cage so it is instantly accessible and not dragging through sand or coral.
How should I store a regulator between dive trips?
Store it fully dry, out of sunlight, with the dust cap in place and the hoses in wide loops rather than tightly coiled. Avoid hanging it by the second stages for long periods, which stresses the hose fittings; laying it flat in a padded bag or hanging it by the first stage is kinder. If it has sat unused for a long stretch, have it checked before your next trip rather than assuming it is ready to dive.
What exactly comes in the Halcyon Singles Reg Package #2 (65.002.004A)?
The package includes one H-75P first stage, one Halo second stage, one Aura second stage, a Master SPG, a single-cylinder hose kit with 84" and 22" LP hoses and a 26" HP hose, a backup necklace cord, and stainless steel bolt snaps in 3/8" and 1" sizes. It arrives as a matched single-cylinder regulator system.
Is the H-75P first stage DIN or yoke?
The H-75P uses a 300-bar DIN connection, with optional yoke compatibility. Contact us to confirm the right fitting for your cylinders.
Can I get a shorter primary hose than the 84 inch long hose?
Yes. Halcyon states the 84" LP hose supplied in this package can be substituted with a 60" LP hose.
What is the difference between the Halo and the Aura second stage in this package?
This package pairs the Halo as one second stage with the Aura as the other. The Aura is an air-balanced, downstream-valve second stage with adjustable breathing resistance and a chrome-plated brass valve, and it is compact and lightweight enough to serve as either a primary or a backup. The Aura second stage and the H-75P first stage are nitrox compatible to 40%.

















