Zeagle Envoy II 1st Stage with Envoy 2nd Stage
In stock — ships from Irvine, CA
This item is currently on backorder. Order now to reserve yours, and we will ship it as soon as it is back in stock.
Zeagle Envoy II 1st Stage with Envoy 2nd Stage - YOKE is backordered and will ship as soon as it is back in stock.
Pickup available at In Store
Usually ready in 2 hours
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Save with Open Box or Used Purchase
Save with a package
Ready-made packages that include this item
Save $299.85 (20% off)
Product Information
Zeagle Envoy II 1st Stage with Envoy 2nd Stage is a scuba regulator set that pairs a lightweight balanced-diaphragm first stage with a downstream-valve second stage and a Dive/Pre-dive Venturi control, built by Zeagle as an economical regulator for use as either a primary or a backup. It ships with a 30-inch hose and is available with a Yoke or a DIN inlet.
Who it is for
Zeagle markets the Envoy II as an economical regulator suitable for use as either a primary or a backup second stage, so it fits divers who want a straightforward, no-frills regulator set or who need a dependable spare to pair with an existing rig.
Key details
- Dry weight: 2.4 lbs (1.1 kg); first stage weight: 1.88 lbs (0.89 kg); second stage weight: 0.42 lb (0.26 kg) without hose
- Ports: 2 high pressure (7/16"-20 UNF) and 5 low pressure (3/8"-24 UNF)
- Intermediate pressure: 135 to 150 psi (9 to 10 bar)
- Hose length: 30 in.
- Environmentally sealed: No; braided hose: No; service interval: 1 year
- First stage body is brass with Buna-N O-rings and a stainless steel HP valve; second stage cover is flexible thermoplastic with a silicone mouthpiece
Compatibility and sizing
The Envoy II is published in two inlet options: Yoke (SKU 350-3310) and DIN (SKU 350-3320). Choose the inlet that matches your tank valve, since the first stage connects differently to Yoke versus DIN valves.
DiveCatalog.com is an authorized Zeagle dealer and a dive shop in Irvine, California, open since 2003. Call 888-701-4017 or chat with us if you have questions about inlet type, fit, or compatibility with your current setup.
- Balanced diaphragm first stage maintains steady intermediate pressure of 135 to 150 psi (9 to 10 bar).
- Downstream valve second stage includes a Dive/Pre-dive Venturi control.
- Dual inlet options available as Yoke (SKU 350-3310) or DIN (SKU 350-3320).
- Port configuration offers 2 high pressure ports (7/16"-20 UNF) and 5 low pressure ports (3/8"-24 UNF).
- Lightweight build totals 2.4 lbs (1.1 kg) dry weight, with the first stage alone at 1.88 lbs (0.89 kg) and the second stage at 0.42 lb (0.26 kg) without hose.
- 30-inch hose connects the first and second stages.
- Not environmentally sealed and does not use a braided hose.
- Annual service interval of 1 year is specified by Zeagle.
- Durable materials include a brass first stage body, Buna-N O-rings, a stainless steel HP valve, a flexible thermoplastic second stage cover, and a silicone mouthpiece.
- Economical design marketed by Zeagle as suitable for use as either a primary regulator or a backup.
| Dry Weight | 2.4 lbs (1.1 kg) |
| First Stage Weight | 1.88 lbs (0.89 kg) |
| Second Stage Weight | 0.42 lb (0.26 kg) without hose |
| HP/LP Ports | 2/5 |
| High Pressure Ports | 2 (7/16"-20 UNF) |
| Low Pressure Ports | 5 (3/8"-24 UNF) |
| Intermediate Pressure | 135 to 150 psi (9 to 10 bar) |
| Hose Length | 30 in. |
| Environmentally Sealed | No |
| Braided Hose | No |
| Service Interval | 1 year |
| Inlet Options | Yoke, DIN |
| First Stage Body Material | Brass |
| O-Ring Material | Buna-N |
| HP Valve Material | Stainless steel |
| Second Stage Cover Material | Flexible thermoplastic |
| Mouthpiece Material | Silicone |
⚠️ WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, visit www.P65Warnings.ca.gov.
Frequently Asked Questions
How often does a scuba regulator need servicing?
Follow the interval in your regulator's manual, since manufacturers commonly specify an annual inspection or a set number of dives and many warranties depend on it. A regulator is life-support equipment, so service belongs with a factory-trained technician rather than being attempted at home. Have it looked at sooner than scheduled if you notice increased breathing effort, free-flow, bubbles, or water in the second stage.
How do I rinse and care for a regulator after diving?
Make sure the dust cap is dry and firmly seated over the first-stage inlet before the regulator goes anywhere near water, because water inside the first stage is the leading cause of internal corrosion. Rinse in fresh water without pressing the purge button, since purging while depressurized can draw water back into the second stage. Shake out the water and hang it to dry with the hoses in wide, gentle loops rather than tight bends.
Can I fly with a scuba regulator?
Regulators travel well and are usually best carried in hand luggage where they will not be crushed or lost. A regulator holds no gas of its own, so there is nothing inherently problematic about it on an aircraft, though the airline and security screeners always have the final say. Pack it dry with the dust cap in place, in a padded regulator bag or wrapped in soft gear.
Can I use my regulator with nitrox?
Many modern regulators are supplied as suitable for nitrox mixes up to 40 percent oxygen, which is the widely used recreational industry standard, while anything above that requires dedicated oxygen-clean equipment and procedures. Confirm what your specific regulator's manual states, and follow your nitrox training and your fill station's requirements. Never assume a regulator is oxygen-service clean simply because it looks clean or is new.
What is the difference between DIN and yoke regulators?
A yoke (A-clamp) fitting clamps over the tank valve and is the most common connection across much of the recreational world, while a DIN fitting screws into the valve and is standard in much of Europe and in technical diving. DIN captures the o-ring inside the threads, which many divers consider more secure, but yoke is often what rental cylinders provide. Adapters exist in both directions, so check what is used where you dive before deciding.
What is the octopus regulator for?
The octopus is your backup second stage, carried so you can share air with a buddy who is out of gas, or breathe from it yourself if your primary fails or free-flows. It is normally on a longer, brightly colored hose so it is easy to find and hand over under stress. Secure it in the triangle between your chin and the bottom of your rib cage so it is instantly accessible and not dragging through sand or coral.
How should I store a regulator between dive trips?
Store it fully dry, out of sunlight, with the dust cap in place and the hoses in wide loops rather than tightly coiled. Avoid hanging it by the second stages for long periods, which stresses the hose fittings; laying it flat in a padded bag or hanging it by the first stage is kinder. If it has sat unused for a long stretch, have it checked before your next trip rather than assuming it is ready to dive.
Can the Zeagle Envoy II be used as a backup regulator (octopus)?
Yes. Zeagle markets the Envoy II as an economical regulator suitable for use as either a primary regulator or a backup second stage, so it can serve either role depending on how you set up your gear.
What warranty comes with the Zeagle Envoy II?
The Envoy II carries a limited lifetime warranty to the original purchaser. Wear items such as filters, hoses, O-rings, diaphragms, and mouthpieces are warranted for two years from the date of purchase, and the warranty requires annual professional servicing.
What is the intermediate pressure of the Envoy II first stage?
The Envoy II's balanced-diaphragm first stage runs an intermediate pressure of 135 to 150 psi (9 to 10 bar).
Is the Zeagle Envoy II environmentally sealed?
No. Zeagle's published specification lists the Envoy II first stage as not environmentally sealed, and it does not use a braided hose. It still requires the standard 1 year service interval.