Zeagle Onyx II 1st Stage Yoke with Onyx 2nd Stage
In stock — ships from Irvine, CA
This item is currently on backorder. Order now to reserve yours, and we will ship it as soon as it is back in stock.
Zeagle Onyx II 1st Stage Yoke with Onyx 2nd Stage - YOKE is backordered and will ship as soon as it is back in stock.
Pickup available at In Store
Usually ready in 2 hours
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Save with a package
Ready-made packages that include this item
Product Information
The Zeagle Onyx II 1st Stage with Onyx 2nd Stage is a complete cold-water regulator set built around a balanced, environmentally sealed first stage and a downstream second stage with a balanced diaphragm. It is offered in Yoke and DIN configurations, carries two HP and five LP ports, and ships with a lightweight 30-inch (.76 m) braided hose at a dry weight of 2.75 lbs / 1.25 kg.
Who it is for
This set suits divers who spend time in cooler water and want a sealed first stage that keeps water and contaminants out of the internal mechanism. The balanced design delivers consistent breathing effort across tank pressures, while the adjustable breathing sensitivity and Dive/Pre-Dive Venturi control let a diver tune the second stage for current, workload or a free-flow-prone descent. With five LP ports, it also works for divers running a primary, an octopus and additional low pressure accessories.
Key details
- First stage: balanced, dry environmental seal, 2 HP and 5 LP ports, lightweight construction with a black finish, and Hydro Transmitter compatibility.
- Second stage: downstream valve with balanced diaphragm, compact profile, anodized aluminum heat sink, Dive/Pre-Dive Venturi control and diver-adjustable breathing sensitivity.
- Hose: lightweight braided second stage hose, 30-inch (.76 m).
- Dry weight: 2.75 lbs / 1.25 kg.
- Service interval: 1 year.
Compatibility and sizing
Choose Yoke (SKU 350-0310) for A-clamp tank valves or DIN (SKU 350-0320) for threaded DIN valves. A first stage HP port accepts the Zeagle Hydro Transmitter for air-integrated computer use.
DiveCatalog.com is an authorized Zeagle dealer and a real dive shop in Irvine, California since 2003. Call 888-701-4017 or start a chat if you are unsure whether DIN or Yoke fits the tanks you dive.
- Balanced first stage delivers consistent breathing performance as tank pressure drops.
- Dry environmental seal keeps water and contaminants out of the first stage for cold-water diving.
- Hydro Transmitter compatible first stage HP port for air-integrated computer setups.
- 2 HP and 5 LP ports allow versatile hose routing and accessory configurations.
- Lightweight first stage construction finished in black.
- Downstream second stage valve with a balanced diaphragm for smooth airflow.
- Dive/Pre-Dive Venturi control lets the diver manage free-flow tendency and breathing assist.
- Diver-adjustable breathing sensitivity for added comfort at different workloads.
- Compact second stage profile with an anodized aluminum heat sink.
- Lightweight braided hose measuring 30 inches (.76 m).
- Dry weight of 2.75 lbs / 1.25 kg.
- DIN and Yoke versions published by Zeagle for different tank valve standards.
| Brand | Zeagle |
| Model | Onyx II Regulator (Onyx II first stage with Onyx second stage) |
| Type | 1st and 2nd stage regulator set |
| Connection Options | Yoke, DIN |
| First Stage Design | Balanced |
| Environmentally Sealed | Yes (dry environmental seal) |
| HP/LP Ports | 2/5 Ports |
| Second Stage Design | Downstream valve, balanced diaphragm |
| Venturi Control | Dive/Pre-Dive |
| Breathing Sensitivity | Diver-adjustable |
| Heat Sink | Anodized aluminum |
| Braided Hose | Yes |
| Hose Length (2nd stage) | 30-inch (.76 m) |
| Dry Weight | 2.75 lbs / 1.25 kg |
| Service Interval | 1 Year |
| Transmitter Compatibility | Zeagle Hydro Transmitter (first stage HP port) |
| SKU (Yoke) | 350-0310 |
| SKU (DIN) | 350-0320 |
| Warranty | Limited lifetime to original purchaser with annual service; hoses, filters, O-rings, diaphragms and mouthpieces covered 2 years |
⚠️ WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, visit www.P65Warnings.ca.gov.
Frequently Asked Questions
How often does a scuba regulator need servicing?
Follow the interval in your regulator's manual, since manufacturers commonly specify an annual inspection or a set number of dives and many warranties depend on it. A regulator is life-support equipment, so service belongs with a factory-trained technician rather than being attempted at home. Have it looked at sooner than scheduled if you notice increased breathing effort, free-flow, bubbles, or water in the second stage.
How do I rinse and care for a regulator after diving?
Make sure the dust cap is dry and firmly seated over the first-stage inlet before the regulator goes anywhere near water, because water inside the first stage is the leading cause of internal corrosion. Rinse in fresh water without pressing the purge button, since purging while depressurized can draw water back into the second stage. Shake out the water and hang it to dry with the hoses in wide, gentle loops rather than tight bends.
Can I fly with a scuba regulator?
Regulators travel well and are usually best carried in hand luggage where they will not be crushed or lost. A regulator holds no gas of its own, so there is nothing inherently problematic about it on an aircraft, though the airline and security screeners always have the final say. Pack it dry with the dust cap in place, in a padded regulator bag or wrapped in soft gear.
Can I use my regulator with nitrox?
Many modern regulators are supplied as suitable for nitrox mixes up to 40 percent oxygen, which is the widely used recreational industry standard, while anything above that requires dedicated oxygen-clean equipment and procedures. Confirm what your specific regulator's manual states, and follow your nitrox training and your fill station's requirements. Never assume a regulator is oxygen-service clean simply because it looks clean or is new.
What is the difference between DIN and yoke regulators?
A yoke (A-clamp) fitting clamps over the tank valve and is the most common connection across much of the recreational world, while a DIN fitting screws into the valve and is standard in much of Europe and in technical diving. DIN captures the o-ring inside the threads, which many divers consider more secure, but yoke is often what rental cylinders provide. Adapters exist in both directions, so check what is used where you dive before deciding.
What is the octopus regulator for?
The octopus is your backup second stage, carried so you can share air with a buddy who is out of gas, or breathe from it yourself if your primary fails or free-flows. It is normally on a longer, brightly colored hose so it is easy to find and hand over under stress. Secure it in the triangle between your chin and the bottom of your rib cage so it is instantly accessible and not dragging through sand or coral.
How should I store a regulator between dive trips?
Store it fully dry, out of sunlight, with the dust cap in place and the hoses in wide loops rather than tightly coiled. Avoid hanging it by the second stages for long periods, which stresses the hose fittings; laying it flat in a padded bag or hanging it by the first stage is kinder. If it has sat unused for a long stretch, have it checked before your next trip rather than assuming it is ready to dive.
Is the Zeagle Onyx II suitable for cold water diving?
Yes. Zeagle builds the Onyx II as a cold-water regulator, and the first stage uses a dry environmental seal that isolates the internal mechanism from water and contaminants. The second stage pairs a downstream valve with a balanced diaphragm and an anodized aluminum heat sink, and Dive/Pre-Dive Venturi control plus adjustable breathing sensitivity let you reduce free-flow tendency at the surface or on descent.
What is the hose length on the Onyx II second stage?
The Onyx II comes with a lightweight braided second stage hose measuring 30 inches (.76 m); the set's dry weight is 2.75 lbs / 1.25 kg. The first stage offers five LP ports, so you can add an octopus or other low pressure hoses in the routing you prefer.
Can I use an air-integrated transmitter with the Onyx II?
Yes. The Onyx II first stage is listed by Zeagle as compatible with the Hydro Transmitter, which threads into a high pressure port. The first stage has two HP ports, and Zeagle lists the Hydro Transmitter as compatible with a first stage HP port. Contact us if you need help confirming port fitment.
What does the Zeagle warranty on the Onyx II cover?
Zeagle provides a limited lifetime warranty to the original purchaser. To keep it valid, the regulator must be serviced annually, within 30 days of the purchase anniversary date. Wear items including filters, hoses, O-rings, diaphragms and mouthpieces are covered for 2 years rather than for life. The published service interval for the Onyx II is 1 year.